With the IIDK Interface object one can manage all the elements of the system. The IIDK Interface object is created under the Computer object  in the Intellect object tree.

Note

To use the IIDK Interface object, allow the relevant functionality in the license key.

Note

If Intellect is started in the demo mode, the IIDK Interface object is activated after the functional module is connected to the system core (see Connect section)

Important!

The ID of the IIDK Interface object must not be the same as the IDs of the Monitor objects created in the system.

If the IIDK Interface object is used, the settings panels are not created for integrated functional modules (third party applications).

When the Intellect distributed architecture is used, the IIDK Interface object must be created on the computer that is running the software core (the core to which the connection is made). If the connection is made to a computer that has the Operator Workstation installed, the connection parameters must include the IP address of the Server or the Administrator Workstation.   