Go to documentation repository
The Intellect section is used for Intellect advanced setup. The settings panel for the Intellect section is shown in the figure.
The parameters of the Intellect settings panel are described in the table.
No | Parameter name | Field type | Description | Representation | Default value | Value range |
1 | The Core IP address field with button. Is set on the Client | Type-in the value in the field/use the button | Set the IP address of the Intellect server to which the slave.exe module is connected by default. | IP address | 127.0.0.1 | Depends on net settings of the Server. In case of connection failure dialog window requiring IP address is displayed |
2 | The Keyboard prefix field | Type-in the value in the field | Set the prefix for a special key-board. When a button is pressed on this key-board the Intellect detects when the button was pressed on this very key-board | Symbol | - | Usually, a tilde (~), code 126 |
The Logging subsystem group | ||||||
3 | The Debug mode dropdown list | Drop-down list item | Set the mode of the Intellect Debug window displaying | List of available modes of Debug window displaying | None | Disabled – Debug window is not displayed. Debug 1 – Debug window is displayed and a log-file containing recordings about modules errors is created. Debug 2 – Debug window is displayed and a log-file containing recordings about modules errors and alerts is created. Debug 3 – Debug window is displayed and a log-file containing recordings about all the modules events is created. Debug 4 – Debug window is displayed and a log-file containing recordings about all the modules events, and also additional menu that is individual for each module (used by programmers) are created. |
4 | The Log-storing time (hours) field | Type-in the value in the field | Set the time of keeping log files | Sequence | 48 hours | > 0 |
5 | The Counters logging time (sec) field | Type-in the value in the field | Assigns the time interval in seconds for logging processor load, memory usage, and disk usage. | Sequence | 60 | Positive whole numbers not less than 60 and zero. If the value 0 is specified, sensor data is not included in the log file. |
6 | The Save logs checkbox | Checkbox | Enables logs saving | Boolean type | Yes | Yes – logs are saved. No – logs are not saved. |
7 | The Redirect to debugger checkbox | Checkbox | Enables the debugger | Boolean type | None | Yes –the debugger is in use. No – the debugger is not in use. |
8 | The Maximum size (MB) field | Type-in the value in the field | Defines the maximum size of RAM that log files can use. Log files are archived after that size is reached. | Sequence | 100 MB | >= 100 Values less than 100 Mb are ignored. |
The JPG and AVI files export path group | ||||||
9 | The Default (Intellect\Exp-ort)/Other switch | Set in the position | Set the folder for exported files from Intellect video archive | - | Default (Intellect\Export) | Default (Intellect\Export) – exported to the C:\Users\%current user name%\Documents\Intellect\export\ folder Other – exported to the selected folder |
10 | The Other field with the button | Click the button/type-in the value in the field | Set the pathname to the folder, where files from video archive are to be exported when the switch is set in the Other position | Pathname | - | - |
11 | The Open folder button | Click the button | Opens the current folder to export the files | - | - | - |
12 | The Record path checkbox | Checkbox | The checkbox forbids export catalogue change while exporting the archive period as well as exporting the archive from AviExport utility. | Boolean type | No | Yes – export catalogue change is forbidden. No – export catalogue change is allowed. |
No group | ||||||
13 | The Receive uncompressed video checkbox | Checkbox | Enables receiving uncompressed video from the Server. As a rule is set on the Client | Boolean type | No | Yes – Client receives uncompressed video from the Server No – Client receives compressed video from the Server |
14 | The Event viewer over all windows checkbox | Checkbox | Enable displaying the Event viewer window over all windows. | Boolean type | No | Yes – the Event viewer window is displayed over all windows. No – the Event viewer window is displayed if a corresponding screen is selected |
15 | The Only local protocol checkbox | Checkbox | Enables logging the events registered in the given computer to the Events protocol database. Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section. | Boolean type | No | Yes – events registered in the given computer are recorded to the Events protocol database No – all required events are recorded to the Events protocol database |
16 | The Sort tree objects by ID checkbox | Checkbox | Enables sorting of objects in the tree by identifier. Note 1. If sorting by name is chosen, and there are numbers in the object name, then the objects will be sorted in alphabetical order. For example, an object with the name "115" will be above the object with the name "15", because in the name "115" the second number is 1, and in the name "15" the second number is 5. Note 2. This key also affects the sorting of objects in the tree when adding the objects to a layer in the Map Editor utility. | Boolean type | No | Yes - objects in the tree are sorted by identifier No - objects in the tree are sorted by name |
17 | The Disable protocol checkbox | Checkbox | Disables events logging to the Event viewer database on this computer. Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section. | Boolean type | No | Yes – events are not logged to the Event viewer database No – events are logged to the Event viewer database |
18 | The Used memory dump checkbox | Checkbox | Enables logging .dmp file with a copy of main memory with incorrect shutting down at least one of the system modules to the Intellect root folder | Boolean type | No | Yes – memory dump is created No – memory dump is not created |
19 | The Support old scripts checkbox | Checkbox | Set the support of program tools in Intellect | Boolean type | No | Yes – both scripts and programs are supported No – only scripts are supported |
20 | The Time synchronization checkbox | Checkbox | Set time synchronization of all computers in the distributed system with system time of this computer. Time is automatically synchronized at midnight every 24 hours or when INTELLECT™ is started on the Server that is the source of time synchronization. | Boolean type | No | Yes – synchronization is enabled No – synchronization is disabled |
21 | The Overlay in Event protocol dropdown list | Drop-down list item | Set the overlay mode for processing the video signals that can be viewed with the help of the Event protocol object | Names of overlay modes | Overlay 2 | None – video signals are not processed by video card Overlay 1 – Direct3D is used Overlay 2 – DirectDraw is used |
22 | The Application language dropdown list | Drop-down list item | Assigns the Intellect Software System's interface language | Names of installed languages | - | Depends on the set of installed languages. The process of installing languages is described in Axxon PSIM Software System's interface language. |