The appearance of the settings panel of the Computer object is shown in the figures. The description of the parameters of the Computer object settings panel is given in the table below the figures.
The Archive Disks and Basic settings tabs:
The Operator tab:
The Protocol synchronization tab:
The Archive synchronization tab:
№ | Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Network name* | Automatically | Displays the computer name in the local network | Latin characters and digits 0..9 | - | Depends on the number of Computer objects registered in the system Number of symbols – from 1 to 15. |
2 | Name* | Enter the value in the field | Set the name of the Computer object in the system | Latin, Cyrillic and service characters | Computer | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Is identified by the check mark | Defines the condition of the Computer object (enabled or disabled) in the system | Boolean type | No | Yes – the Computer is disabled and is not in use No – the Computer is enabled and is in use. |
Disks for Archive Storage | ||||||
4 | Video | Is identified by the check mark | Set the disk for storing video archive from cameras and also audio archive during synchronous audio and video recording | Boolean type | No | Yes – the disk is used for video archive storing No- the disk is not used for video archive storing |
5 | Audio | Is identified by the check mark | Set the disk for storing audio archive from microphones | Boolean type | No | Yes – the disk is used for video archive storing No- the disk is not used for video archive storing |
6 | Disk | Automatically, specify the value in the field | Displays the names of local disks, accessible for storing video and audio archive, and also used to specify the network disks used for archive storing. | Names of local disks (Latin characters), names of network disks (UNC-pathes) | - | Depends on the total number of local and network disks |
7 | GB | Automatically | Contains information about free space on the every accessible disk | Disk space in GB | - | Depends on the total free disk space |
8 | Recording | Automatically, set the checkbox checked | Show current disk for storing archive | Boolean type | No | Yes – the archive is currently stored on the specified disk. No – the archive is not currently stored on the specified disk. |
Settings Group | ||||||
9 | Connection | Enter the value in the field | Gives the name to the modem connection used in the Windows OS. | Latin, Cyrillic and service characters | - | A line containing a sequence of any symbols (letters, digits, service characters) Number of symbols – from 1 to 30. |
10 | Username | Enter the value in the field | Sets the login name for the existing Windows modem connection. | Latin, Cyrillic and service characters | - | A line containing a sequence of any symbols (letters, digits, service characters), case-sensitive. Number of symbols – from 1 to 30. |
11 | Password | Enter the value in the field | Sets the password for the existing Windows modem connection | Latin, Cyrillic and service characters | - | A line containing a sequence of any symbols (letters, digits, service characters), case-sensitive. Number of symbols – from 1 to 30. |
12 | Disable record-keeping | Is identified by the check mark | Switches off storing of events to the Event viewer database on the local computer. | Boolean type | No | Yes - events are not stored to the Event viewer database No - events are stored to the Event viewer database |
13 | Only local protocols | Is identified by the check mark | Activates logging to the database the Events viewer only information about events, registered on the given computer | Boolean type | No | Yes – only events, registered at this computer are logged to the database the Events viewer No – events, registered at this computer are not logged to the database the Events viewer |
14 | Time synchronization | Checkbox | Set time synchronization of all computers in the distributed system with system time of this computer. Time is automatically synchronized at midnight every 24 hours or when INTELLECT™ is started on the Server that is the source of time synchronization. | Boolean type | No | Yes – time is synchronized No – time is not synchronized |
15 | Events archive length | Type-in the value in the field | Sets the period of time for the events to be stored in the Event viewer database | Days | - | More than 1 |
16 | Run x64 modules checkbox | Setting checkbox | Specifies the way of launch of 64-bits modules | Boolean type | Up to 4.10.2 – No From 4.10.3 – Yes | Yes - 64-bits module launches when the module launch attempt. If such variant is not found the 32-bits module launches. No - 64-bits modules are not launch |
17 | Use as client checkbox | Checkbox | Computer is used as the Client in the distributed video surveillance system | Boolean type | No | Yes – computer is used as Client. No – computer is used as Server or RAW. |
18 | Prevent Sleep mode checkbox | Checkbox | If the checkbox is selected when Intellect is running, Windows OS sleep mode will be disabled. | Boolean type | Yes | Yes - computer doesn’t go into sleep mode No - computer can go into sleep mode |
19 | Initial display | Is selected from the list | Set the screen to be displayed on default after starting of the Intellect digital video surveillance system. The last active Display is displayed after the Intellect restart if no one screen is selected. | Names of the Display objects registered in the system | - | Depends on total number of Display objects registered in the system. |
20 | Default user | Is selected from the list | Defines a default user, i.e., the user, the rights and authorities of which will be used to launch Intellect™ software without a password. | Names of the users registered in the system. | - | List of users registered in the Intellect™ system. |
21 | Camera discovery tool | Press the button | Access to creating, settings and editing of IP devices. | - | - | - |
Operator | ||||||
22 | Speaker | Is selected from the list | Allows selecting the speaker that is to be in use for audio playback (use when SIP devices are installed in video surveillance system – see Configuring SIP-terminal). | Names of the Speaker objects registered in the system | - | Depends on number of the Speaker objects registered in the system |
23 | Microphone | Is selected from the list | Allows selecting the microphone that is to be in use for audio transmission (use when SIP devices are installed in video surveillance system – see Configuring SIP-terminal). | Names of the Microphone objects registered in the system | - | Depends on number of the Microphone objects registered in the system |
24 | Camera | Is selected from the list | Allows selecting the camera that is to be in use for video transmission (use when SIP devices are installed in video surveillance system – see Configuring SIP-terminal). | Names of the Camera objects registered in the system | - | Depends on number of the Camera objects registered in the system |
Protocol synchronization | ||||||
25 | Synchronize | Is identified by the check mark | Set the synchronization of database The Events viewer of local and remote computers | Boolean type | No | Yes– database the Events viewer of local and remote computers are synchronized No– database the Events viewer of local and remote computers are not synchronized |
26 | Computer | Automatically | Displays the net name of remote computer with which database the Events viewer must be synchronized | Latin alphabet and service characters | - | Depends on the number of computers, registered in the system |
27 | Name | Automatically | Displays the name of remote computer in the net | Latin, Cyrillic and service characters | A line containing a sequence of any symbols (letters, digits, service characters), case-sensitive. Number of symbols – from 1 to 60. | |
28 | Change connection string | Press the button | Access to settings and editing the parameters of connection to the database the Events viewer of remote computer | - | - | - |
The Archive synchronization tab | ||||||
29 | Number | Select in the list | Sets the ID of camera the archive of which is to be synchronized when restoring the main Server (see also Configuring archive synchronization of main and backup Servers). | IDs of the Camera objects created in the object tree of the main Server | - | Depends on the number of the Camera objects registered in the system |
30 | Name | Select in the list | Sets the name of camera the archive of which is to be synchronized when restoring the main Server (see also Configuring archive synchronization of main and backup Servers). | Names of the Camera objects created in the object tree of the main Server | - | Depends on the number of the Camera objects registered in the system |
31 | Backup archive | Select in the list | Sets the Backup archive object configured to cooperate with the Failover service and used for synchronization of archive of the main and backup Servers. | Names of the Backup archive objects registered in the system | - | Depends on the number of the Backup archive objects registered in the system |
32 | Range | Click the button | Opens a dialog box for bulk camera selection | - | - | - |
33 | All | Click the button | Adds all created cameras to the table | - | - | - |