Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

The SIP-panel is configured as follows:

  1. Go to the Basic settings tab of the SIP-panel object.
  2. Set the coordinates of the SIP-panel interface window in one of the following ways:
    1. Manually:
      1. Set the coordinates of the upper left corner of the interface window: the X (horizontal indent from the left edge of the screen) and Y (vertical indent from the upper edge of the screen) fields. The coordinates are expressed as a percentage of the horizontal and vertical screen dimensions, respectively (1).
      2. Set the dimensions of the interface window: the W (window width) and H (window height) fields. The dimensions are expressed as a percentage of the horizontal and vertical screen dimensions, respectively (2).
    2. Using the test window: 
      1. Click the X button (3).
      2. Position the Specify dimensions test window where the SIP-panel should be displayed. 

      3. Click the OK button. As a result, the coordinates in the X, Y, W, H fields will be set according to the dimensions and position of the test window. 
  3. From the Monitor drop-down list (4), select the computer monitor on which the interface window will be displayed.
  4. From the Terminal drop-down list (5), select the SIP-terminal object which SIP-devices use the SIP-panel.

    Note

    Each Server/Remote Client should have its own display with its own SIP-panel (see Assigning the displays to the operator workstations). If the display with this SIP-panel is already selected for any computer, the Terminal drop-down list will be inactive. It is necessary to fix the incorrect configuration of the Server/Remote Client.

  5. From the Monitor drop-down list (6), select the Monitor object corresponding to the Video Surveillance Monitor to which the video cameras associated with the corresponding SIP-devices are added. For details, see Selecting and configuring video cameras.
  6. Click the Apply button (7).

The basic settings of the SIP-panel interface object are now configured.