Manufacturer

Honeywell Systems Group
Video and Access Control Solutions
Aston Fields Road
Whitehouse Industrial Estate
Runcorn
Cheshire
WA7 3DL
United Kingdom
Tel: +44 (0)8448 000 235
Fax: + 44 (0)01928 754050
Email: sales.video.uk@honeywell.com
www.security.honeywell.com

Integration type

Software integration

Equipment connection

RS-232, RS485, Ethernet

Supported equipment

Equipment

Function

Features

Honeywell Pro3200

Access control module

  • up to 9 modules, power-supply and battery can be accommodated by the PRO22ENC1, PRO22ENC2 and PRO22ENC5 (no battery) enclosures
  • user programmable relay outputs allow for specific control needs
  • user programmable alarm inputs offer flexible system configuration and control
  • RS485 communication to all modules
  • Analog to digital converter technology provides digital filtering and input conditioning
  • dedicated cabinet tamper and power monitor inputs
  • supports the choice of normally open, normally closed, supervised, and nonsupervised circuits
  • supports a wide range of reader technologies including Wiegand, magnetic stripe, proximity, and keypad
  • system off-line modes customizable per reader include facility code access, locked (no access), and unlocked (full access)
  • supports multiple reader and card formats for maximum flexibility and security options
  • operating modes include locked, unlocked, facility code, card only, card and PIN, card or PIN and PIN only
  • communication to the host is via either 10/100 Ethernet or RS-232 (both are standard)
  • alarm circuit type - normally open, normally closed, non-supervised, supervised (with correct EOL). Meets requirements for UL294 and CUL
  • any combination of 16 I/0 or readers modules may be connected to the PRO32IC RS485 ports. 4,000 ft (1,250 m) total bus length per port
  • over 50 000 cards
  • over 50 000 transactions

Licensing

For one reader and input. There are three price-list positions for the integration module:

  1. INTELLECT Access Control Service (WIN-PAK Main Object), per system – to be included on a mandatory basis, as it allows creating the WIN-PAK Main Object in ACFA Intellect tree.
  2. INTELLECT Access Control Service (WIN-PAK Card Reader), per reader – is included if readers are in use, the number of positions in the order shall be equal to the number of entrances.
  3. INTELLECT Access Control Service (WIN-PAK Input), per package – is included if alarm inputs are in use; the position allows the use of 16 inputs in ACFA Intellect, e.g. add 2 positions for 24 inputs. 