Go to documentation repository
Documentation for ACFA PSIM 1.3.
Previous page Next page
The system settings of the Virdi Terminal are set up as follows:
- From the Security Level 1:1 (Verify) drop-down list (1), select the verification quality level from 1 to 9 if only one type of authentication is used. The default value is 4.
- From the Security Level 1:N (Identify) drop-down list (2), select the authentication quality level from 1 to 9 if several authentication types are used. The default value is 5.
From the Input ID Length drop-down list (2), select the user ID length: from 4 to 8 symbols.
Attention!
To ensure the terminal operation with ACFA-Intellect, it is necessary to select the 8 value. Also, the Input ID Length should be set to 8 in the terminal itself.
- Set the Automatic Enter key check box (4) to enable the automatic key entry from the terminal keyboard (F1-F4 buttons).
- From the Sound volume drop-down list (5), select the terminal speaker volume level: from 0 to 20.
- From the Authentication mode drop-down list (6), select the mode of authentication and terminal operation:
- Server / Terminal - the decisions are made by the Server, and if it is not available, then by the terminal.
- Terminal / Server - the decisions are made by the terminal, and if it is not available, then by the Server.
- Server - the decisions are made by the Server.
- Terminal - the decisions are made by the terminal.
Offline mode - the offline mode of the terminal.
Note
In the offline mode, the terminal cannot be managed from the ACFA-Intellect Server.
- From the Application mode drop-down list (7), select the terminal operating mode:
Access control - access point mode.
Attention!
To ensure the terminal operation with ACFA-Intellect, it is necessary to select the Access control operation mode.
- Time/Attendance - working time tracking mode.
- Drinking Water - breathalizers compatibility mode.
- From the Antipassback drop-down list (8), select the double-entry control mode:
- Not use - not used.
- Access when disconnected - allow entry if the connection with the Server is lost.
- Prohibit when disconnected - prohibit entry if the connection with the Server is lost.
- From the Input ID type drop-down list (9), select the type of user identifiers:
- UserID type - custom user identifiers.
- UniqueID - unique user identifiers specified in the terminal.
- From the Access mode drop-down list (10), select the access mode provided by the terminal if there is no keyboard for entering numbers on the terminal:
- No restrictions - no restrictions.
- Only fingers and password - only fingerprints and password.
- Click the Apply button (11) to apply the settings.
The operation settings of the Virdi Terminal are set up
Overview
Content Tools