Documentation for ACFA PSIM 1.3.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

The Hikvision DS-K1F100 control reader is configured as follows:

  1. Create a Hikvision Control Reader K1F100 object based on the Computer object on the Hardware tab of the System Settings dialog box.
  2. From the Card save mode drop-down list (1), select the format for saving the facility code and card code:
    • Hikvision format - saves all access cards in the Hikvision format (the facility code contains a fixed H character, the card code is a decimal number up to 32-bits).
    • Hikvision W26 text format - saves all access cards in Hikvision format, and the original facility code is added to the beginning of the card code.
    • Card + Facility code - saves EM-Marine access cards in Wiegand-26 format.

      Attention!

      Card + Facility code only works for EM-Marine Wiegand-26 access cards. Other types of cards will be saved in Hikvision format.

  3. Click the Apply button (3) to save the settings.

The configuration of the Hikvision DS-K1F100 control reader is completed.

  • No labels