To configure PTZ control, do as follows:

  1. Go to the Options tab → Settings →PTZ Settings (1-2).

  2. Set the operator idle time in hours, minutes and seconds (3). When the time runs out, the PTZ control is unlocked automatically if the operator did not carry out any actions.
  3.  By default, if the higher priority user controls the PTZ camera, then the PTZ control panel displays the name of the user. To disable the display of this information, unset the corresponding checkbox (4).
  4. Set Joystick device sensitivity (5, see Joystick Configuration). The sensitivity range will depend on the repository for a particular device.

    Note

    For example, it is written in the Axis T8311 repository:

    <property id="deviceSensitivity" xsi:type="PropertyIntRangeType">
    <value>
    <min>5</min>
    <max>100</max>
    <default>50</default>
    </value>
    </property>

    The working range will be from 5 to 100 for this device.

  5. Click the Apply button.

You have configured PTZ control.