Go to documentation repository
Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.
The AGRG-IO-16/8-WD-DS Sensor-Relay card is an interface of external sensors and external executive devices (relays) as a part of video surveillance and fire and security alarm systems.
The figure shows the appearance of AGRG-IO-16/8-WD-DS card.
The layout of card connectors:
The device is controlled via the USB interface. Electrical and technical specifications of the card are given in the Electrical and technical specifications of AGRG-IO-16/8-WD-DS devices section.
Connect the AGRG-IO-16/8-WD-DS card to the Server as follows:
- Switch the computer power supply off. Remove the system cover.
- Install the AGRG-IO-16/8-WD-DS card into a vacant motherboard slot and fix it in the casing.
- Connect the loop (bundled with the distribution kit) to the J1 connector and to a vacant USB connector on the motherboard of computer.
- To activate the hardware control of the hang, connect the wires to the H2 H3 connector.
- To connect sensors and relays unsolder the connector bundled with the distribution kit.
The connecting wires from the executive devices are soldered to the contacts marked as "Relay" (see the table below).
Connector Application Connector Application 1 Relay 1 (+) 26 Sensor 5 2 Relay 1 27 Sensor 5 3 Relay 2 28 Sensor 6 4 Relay 2 29 Sensor 6 5 Relay 3 30 Sensor 7 6 Relay 3 31 Sensor 7 7 Relay 4 32 Sensor 8 8 Relay 4 33 Sensor 8 9 Relay 5 34 Sensor 9 10 Relay 5 35 Sensor 9 11 Relay 6 36 Sensor 10 12 Relay 6 37 Sensor 10 13 Relay 7 38 Sensor 11 14 Relay 7 39 Sensor 11 15 Relay 8 40 Sensor 12 16 Relay 8 41 Sensor 12 The connecting wires from the sensors are soldered to the contacts marked as "Sensor" (see the table below).
Connector Application Connector Application 17 Sensor 1 42 Sensor 13 18 Sensor 1 43 Sensor 13 19 Sensor 2 44 Sensor 14 20 Sensor 2 45 Sensor 14 21 Sensor 3 46 Sensor 15 22 Sensor 3 47 Sensor 15 23 Sensor 4 48 Sensor 16 24 Sensor 4 49 Sensor 16 25 + 12V (Output) 50 GND (Ground)
- Fix the unsoldered connector in the casing bundled with the distribution kit.
- Connect ready-for-use connector to external connector of the card in order to connect sensors and relays to the Server.
The AGRG-IO-16/8-WD-DS card is now connected.