Documentation for Face PSIM 1.0.1.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

If it is necessary to skip the video frames, do the following:

  1. Go to the C:\Program Files (x86)\SDK_data\profiles\ folder.
  2. Open the default.xml configuration file for editing.
  3. Set the false value to the MultiTracker_exhaustiveTracking key. The default value is true.
  4. Set a larger value to the MultiTracker_detectionFrequency key (within the fps range). The default value is 2.
  5. Save changes to the default.xml configuration file.
  6. Restart Axxon PSIM.

The frames skip of the STC recognition module is configured.

  • No labels