The settings panel of the System restart service object is shown in figure.
Table describes the parameters of the object settings System restarting service.
№
| Name of parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Field Identification number | Automatically | Displays the object’s identification number System restart service in the system
| Sequence of numbers | - | From 1 and above. Depends on the number of objects System restart service in the system
|
2 | Field Name | Enter the value in the field | Defines the name of the object System restart service in the system
| Latin, Cyrillic and service characters | System restarting service | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), case-insensitive Number of symbols – from 1 to 60.
|
3 | Checkbox Disable | Is identified by the check mark | Defines the condition (enabled or disabled) of the System restart service in the system
| Boolean type | No | Yes – the System restart service is disabled and is not in use No – the System restart service is enabled and is in use.
|
4 | Dropdown list Computer | Is selected from the list | Defines the parent Computer object in the system , to which the given object System restart service refers
| Name of the Computer objects registered in the system | Name of the parent Computer object. | Name of the parent Computer object( object System restarting service must not be edited remotely)
|
5 | Checkbox AxxonSoft USB Watch Dog for Slave.exe | Is identified by the check mark | Activates computer system of automatic restarting with the albescence of slave.exe. process’s activity | Boolean type | No | Yes – system of automatic restarting is activated No – system of automatic restarting is deactivated
|
Control table of Intellect modules operation | ||||||
6 | Column Module | Automatically | Displays the list of started modules at the computer | Name f started modules | - | Depends on the number of modules, registered in the system |
7 | Column Status | Automatically | Displays current state of modules | Name of current states and modules | - | Loaded–module operates Unloaded (red field) – on the expiry of waiting time interval module’s response is abscent Unloaded – module is unloaded. Note. In the square brackets the time of module working since the last restartin the HH:MM:SS format is displayed |
8 | Column Response time, sec | Entering of text in the field | Set waiting time interval of module’s response in seconds. With the absence of response on the expiry of set time interval the system may be restarted. | Nonnegative integers | 60 | From 0 and above |
9 | Column Quantity of restarts | Entering of text in the field | Set the maximal quantity of restarts for a period of time, specified in the column In time and Period type | Nonnegative integers | 3 | From 0 and above |
10 | Column In time | Entering of text in the field | Set period of time for which maximal quantity restarts of the system may be performed | Nonnegative integers | 1 | From 0 and above |
11 | Column Period type | Selection of value from the list | Unit s of time measurement | hours | hours –time period is measured in hours days – time period is measured in days | |
12 | Column Restart | Selection of value from the list | Set the type of system’s restarting | Name of possible types of restarts | Nothing | Nothing – restarting is not being performed Module – module’s restarting is being performed Core set – restarting of the Intellect core set is being performed |
13 | Column Remains of restarts | Automatically | Displays remains or restarts for a time period, set in the columns In time and Type of period | Nonnegative integers | - | Depends on the maximal quantity of restarts and on the fact how many restarts have been performed for a current time period |
14 | Memory (Mb) column | Setting the value in the field | Specifies the threshold of memory consumed by module. When this threshold exceeded the restart is required | Integer non-negative numbers | 0 | From 0 and above |