The Web-server object is used for video surveillance via the Internet browser and the TCP/IP communication environment.

The settings panel of the Web-server object is shown in the figure.

The Basic settings tab.

The List of cameras tab.

Table describes the setting parameters corresponding to the elements of the settings panel of the Web-server object.

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Web-server object in the digital video surveillance system with the distributed architecture

Sequence of numbers

-

From 1 and above.

Depends on the number of the Web-server objects in the digital video surveillance system with the distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Web-server object in the digital video surveillance system with the distributed architecture

Latin, Cyrillic and service characters

Web-server

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Web-server object in the digital video surveillance system with the distributed architecture

Boolean type

Clear

Setthe Web-server object is disabled and isn't used

Clearthe Web-server object is enabled and used

4

Computer

Select the value from the list

Sets the Computer parent object of the digital system with the distributed architecture, to which the given Web-server object belongs

Name of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture

The HTTP-server group

5

Port number

Enter the value into the field

Sets the number of the port used by the HTTP-server (used for video surveillance via the Web-browser, including via the Internet)

Sequence of numbers

80

Any valid unused port numbers.

The number of ports is determined by the system administrator.

6

Number of connections

Enter the value into the field

Sets the maximum possible number of connections to the Server via the Web-server module.

Each request to view the video signal from each camera and each request to control all PTZ devices regadless of their number is considered as a connection

pcs

100

Any integer.

If 0 value is specified on the Video Monitor of the Web-server module, video signals won't be displayed

Not in a group

7

Default user

Select the value from the list

Sets the user with rights and authority to conduct the video surveillance from the Remote workstation using the Web-server module

Names of the users registered in the system and added to the rights

Not defined

Depends on the number of the users registered in Intellect

8

ECHD translation

Set the checkbox

Enables to use the http requests used for integration with ECHD

Boolean type

Clear

Setrequests used for integration with ECHD are run for the Camera objects on the basis of which the ECHD channel objects are created

Clearrequests used for integration with ECHD are not run

9

RTSP-server

Select value from the list

Sets rtsp server to process ECHD requests

Names of rtsp Server objects registered in the system

Not set

Depends on the number of rtsp Server objects in distributed digital surveillance system.

10Use NAT addressSet the checkboxEnables router address substitution in ECHD requestsBoolean typeNoYes – when requesting the URL of streams through the HTTP API, the IP address of the router specified in the settings panel of the RTSP Server object is substituted in response to the request.

No – when requesting the URL of streams through the HTTP API, the IP address of the Server in its local network is returned in response to the request.

The HTTPS server group

11

Use HTTPS protocol

Set checkbox

Enabling HTTPS protocol when transferring data via Web-server.

Boolean type

No

Yes – HTTPS protocol is in use.

No – HTTPS protocol is not in use.

12

Enter key

Enter the value in the field

Key for data communication via HTTPS protocol.

Latin, Cyrillic letters and service characters

C:\Program Files (x86)\ Intellect\Modules\SSL\ssl_internal.key

Depends on the location of data encryption key when transferring data via HTTPS protocol.

13

Certificate

Enter the value in the field

Certificate for data communication via HTTPS protocol.

Latin, Cyrillic letters and service characters

C:\Program Files (x86)\Intellect\Modules\SSL\ssl_internal.cert

Depends on the location of certificate file when transferring data via HTTPS protocol.

14

Port number

Enter the value in the field

Sets the number of the port used for HTTPS server (used for video surveillance in the web browser and in the Internet).

Natural number series

443

Any allowable port numbers that are not in use.

The number of ports is specified by the system administrator.

The List of cameras tab

15

Range

Click the button

The box for adding cameras as a group is opened.

-

-

-

16

Clear

Click the button

The list of added cameras is cleared.

-

-

-

17

Add all

Click the button

All Camera objects created in the system are added to the list.

-

-

-








18

Number

Selected in the list

Sets the number of the camera video from which is transmitted to the remote workstation using the Web-server module. 

IDs of the Camera objects registered in the system

Not specified

Depends on the number of cameras in the distributed video surveillance system.

19

Camera

Selected in the list

Sets the name of the video camera video from which is transmitted to the Remote Workstation via the Web-server module.

Names of the Camera objects registered in the system

Not set

Depends on the number of video surveillance cameras in the digital distributed video surveillance system

20

Video stream

Selected in the list

Sets the number of the video stream used for displaying in the Web-server interface 

Numbers of video streams enabled on the camera and the By default value

By default

Depends on the number of enabled streams on the camera.

21

Live video

Selected in the list

Sets the source of live video to be displayed in the Web-server interface

Available means to get live video

Server

Server – live video is received from the Server to which the camera is connected.

Videogate – live video is received from the Videogate.  If a camera is not configured to transmit video through the Videogate, then this item is unavailable in the list.

22

Archive

Selected in the list

Sets the source of archive footage to be displayed in the Web-server interface

Available means to get archive video

Server

Server – archive footage is received from the Server to which the camera is connected.

Videogate – archive footage is received from the Videogate.  If a camera is not configured to transmit footage through the Videogate, then this item is unavailable in the list.

Backup archive – archive footage is received from the Backup archive 

23

Microphone

Select from a list

Specifies the name of microphone associated with the camera from which the sound will be passed through the Web-server

Names of registered Microphone objects in the system

Not specified

Depends on the number of microphones in the video surveillance system

24

Speaker

Select from a list

Specifies the name of speaker associated with the camera which will be in use to playback sound received from the client

Names of registered Speaker objects in the system

Not specified

Depends on the number of speakers in the video surveillance system

25

Compressionn

Selected in the list

Sets the compression ratio for video transmitted to Remote Workstations via the Web-server module. The higher the compression ratio the worse the video signal is.

Reference compression ratios

Not specified

Not specified, 1 – 5.

Value “1” corresponds to minimum compression ratio, “5” – to maximum.

If the compression ratio is not specified, video signal is transmitted with the same compression ratio as set for recording and  transmitting video

26

Control

Selected in the list

Sets the camera control (arm/disarm, PTZ, recording to the archive) in accordance with user rights.

Boolean type

Enabled

Enabled – camera control in accordance with user rights is enabled.  

Disabled – camera control is disabled regardless of  the user rights.

27PTZ controlSelected in the listSet the prioritiy for the PTZ control using the web browserNames of the PTZ control prioritiesLow priority

Forbidden – option of the PTZ control in web browser is disabled

Low priority – low priority of control

Medium priority – medium priority of control

High priority – high priority of control

*The name of the element is not displayed in the settings panel of the given object.