The Control panel object is used to register and configure a specialized control panel used to manage the PTZ devices in Intellect.

The settings panel of the Control panel object is shown in the figure.

Table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Control panel object in the digital video surveillance system with the distributed architecture

Sequence of numbers

-

Depends on the number of the Control panel objects in the digital video surveillance system with the distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Control panel object in the digital video surveillance system with the distributed architecture

Latin, Cyrillic characters and service characters

Control panel

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of characters from 1 to 60

3

Disable

Set the checkbox

Sets the state of the Control panel object (enabled or disabled) in the digital video surveillance system with the distributed architecture

Boolean type

Clear

Set the Control panel object is disabled and isn't used

Clear the Control panel object is enabled and is used

4

Telemetry Controller

Select the value from the list

Sets the Telemetry Controller parent object of the digital system with the distributed architecture, to which the given Control panel object belongs

Name of the Telemetry Controller objects registered in the system

Name of the Telemetry Controller parent object

Depends on the number of telemetry controllers in the digital video surveillance system with the distributed architecture

The Settings group

5

Port

Select the value from the list

Sets the number of the computer serial (COM) port used to connect the Control panel

List of available COM ports 

COM1

Depends on the number of COM ports on the Server or Remote Administrator's workstation

6

Speed

Select the value from the list

Sets the data communication speed of the serial (COM) port

Kb/s


9600

From 300 to 256000

7

Parity

Select the value from the list

Sets the parity check mode for the data transmission over the serial (COM) port

List of the parity check modes

None

Even, Odd, None, Mark, Space

8

DTR

Set the checkbox

Sets whether or not the power should be supplied to the Control panel via the output of the DTR serial (COM) port

Boolean type

Set

Set the power will be supplied via the DTR port output

Clear the power will not be supplied via the DTR port output

9

RTS

Set the checkbox

Sets whether or not power should be supplied to the Control panel via the output of the RTS serial (COM) port

Boolean type

Set

Set the power will be supplied via the RTS port output

Clear the power will not be supplied via RTS port output

10

Priority

Select the value from the list

Sets the priority of the PTZ devices control using the Control panel

Names of priorities used to control the PTZ devices

Low

Control prohibited the PTZ device cannot be controlled using the Control panel

Low the PTZ device can be controlled after it is controlled by the devices with the standard or high priority

Standard the PTZ device can be controlled after it is controlled by the device with the high priority

High the PTZ device is controlled first

*Name of the element is not displayed in the settings panel of the given object.