The settings panel of the SIP-panel object is shown in the figures below.

Table describes the setting parameters of the SIP-panel interface object.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Position group

1


X

Enter the value into the field

Sets the X coordinate in the horizontal axis for the upper left corner of the SIP-panel interface window

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors

Y

Enter the value into the field

Sets the Y coordinate in the vertical axis for the upper left corner of the SIP-panel interface window

% of the screen height

-

From 0 to M*100, where M is the number of the installed monitors

2



W

Enter the value into the field

Sets the width of the SIP-panel interface window

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors

H

Enter the value into the field

Sets the height of the SIP-panel interface window 

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors

3The × buttonClick the button

Opens a test window for changing the coordinates of the SIP-panel interface window

---
4MonitorSelect the value from the list

Sets the number of the monitor in the system for which the coordinates are specified

Numbers of the monitors in OS1From 1 to 16

The Basic settings tab.

Table describes the parameters of the Basic settings tab.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1TerminalSelect the value from the listSets the SIP-terminal object, which SIP-devices use the SIP-panelName of the SIP-panel objects registered in the system-Depends on the number of the SIP-terminal objects in the system
2MonitorSelect the value from the listSets the the Monitor object corresponding to the Video surveillance monitor to which the video cameras associated with the corresponding SIP-devices are addedName of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system

The Advanced settings tab.

Table describes the parameters of the Advanced settings tab.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Interface behavior group

1

The Display only when calling checkbox

Set the checkbox

Displays the SIP-panel interface object only at call

Boolean type

No

Yesthe SIP-panel is only displayed during call

Nothe SIP-panel is always displayed

2The New calls to the end checkboxSet the checkboxEnables adding new calls to the end of the listBoolean typeNo

Yes – new calls are added to the end of the list

No – new calls are added to the top of the list

3The Disable keypress sound checkboxSet the checkboxMutes the sound of keyspress on the SIP-panelBoolean typeNo

Yes – keypress sound disabled

No – keypress sound is turned on

4The Maximize screen on call checkboxSet the checkboxEnables automatic display switching at callBoolean typeNoYeswhen a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically

No – when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen is not displayed automatically

5The Calls to unknown users checkboxSet the checkbox

Enables the option to call unknown subscribers

Note. Unknown user is a number that is present in the SIP-terminal, but not in the address book of the current SIP-operator

Boolean typeYes

Yes - calls to unknown subscribers are allowed

No - calls to unknown subscribers are not allowed

The Interface elements group
6The Dial pad checkboxSet the checkboxDisplays the dial pad in the interfaceBoolean typeYes

Yes - the dial pad is displayed

No - the dial pad is hidden

The Caption checkboxSet the checkboxDisplays the tab names in the interface. When disabled, only the Call tab will be displayed without displaying the nameBoolean typeYes

Yes - the tab names are displayed

No - only the Call tab is displayed without displaying the name

The Archive checkboxSet the checkboxDisplays the Archive tab in the interfaceBoolean typeYes

Yes - the Archive tab is displayed

No - the Archive tab is hidden

The Call control buttons checkboxSet the checkboxDisplays the buttons at the bottom of the call control panelBoolean typeYes

Yes - call control buttons are displayed

No - call control buttons are hidden

The Operator settings tab.

The table describes the parameters of the Operator settings tab.

ParameterMethod for specifying the parameterParameter descriptionPresented asDefault valueRange of values

1

The Operators tableSelect in the columnSets the list of SIP-operators who can work with this SIP-panel---
The Number columnSelect in the listSelects a SIP-operator identifierIdentifiers of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
The Subscriber columnSelect in the listSelects a SIP-operator numberNumbers of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
The Name columnSelect in the listSelects a SIP-operator name in IntellectNames of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
2The All buttonClick the buttonAdds all existing SIP-operators to the table---
3The Range buttonClick the buttonOpens the Add operators window to add multiple SIP-operators---
4The Default drop-down listSelect in the listSets the default SIP-operator-Select on start
  • Select on start - when you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time you will be logged in under the previously selected SIP-operator

  • User rights - you will log into the SIP-panel as the SIP-operator that is linked to the Intellect user rights. You should also be logged into Intellect with the corresponding user rights

  • SIP-operator from the list - logging into the SIP-panel will be made at once as the selected SIP-operator. Depends on the number of SIP-operator objects in the system