The GATE object corresponds to the Videogate system object.

The GATE object sends events presented in the table. Procedure is started when the corresponding event appears.

Format of events procedure for the Videogate object:

OnEvent("GATE ","_id_","_event_")

Events

Description

Comment

GATE_LOW_FPS

Input speed on the gate is reduced


ACTIVE

Gate is active

Event is generated when list of worked cameras corresponds to the list of Videogate configuration

INACTIVE

Gate is inactive

Event is generated when there are no requests for video flows through the Videogate

ACTIVE_PART

Partial work of gate

Event is generated if number of worked cameras is less than in the gate list

Example.  Send corresponding messages to all system cores while reducing the input speed.

OnEvent("GATE ","1"," GATE_LOW_FPS ")
{
  NotifyEventGlobal ("GATE ","1"," GATE_LOW_FPS ");
}