The Equipment detection (PPE) module is configured on the settings panel of the Equipment detection (PPE) object created on the basis of the Camera object on the Hardware tab of the System settings dialog window.
The Equipment detection (PPE) module is configured as follows:
In the Number of frames for analysis and output field (5), enter the minimum number of frames on which a violation should be detected in order to generate a trigger. The value should be in the [2; 20] range.
By default, the detection triggering is generated for each equipment violation. If it is necessary to generate a trigger once for each equipment item violation within a whole person's track, then uncheck One event per equipment element checkbox (6).
Note
Example. A person appeared in the frame without a helmet, then put it on and then took it off again. If the One event per equipment element checkbox is set, then there will be one trigger, if not — two.
Set the Save tracks to show in archive checkbox (8) to save the track in the archive.
Note
The frame on the image of the detected object is saved in the Monitor object archive.
From the Working mode drop-down list (9) select the device on which the neural network will operate.
Click the Settings button (10). The Detector settings window will open.
The Equipment detection (PPE) module is now configured.