Documentation for WEB Report System PSIM 1.0.1.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

To enable the Employee details (full report), do the following:

  1. Go to <Axxon PSIM installation directory>\Modules\Wt2.
  2. Open the Web.config configuration file for editing.
  3. Set the value of the EnableAboutUsersFullReport key to true. The default value is false.

  4. Save the changes in the edited Web.config file.

The parameters of the Web.config file are described in XML-file parameters reference guide.

Note

The Web.config file configuration must be performed on the computer where it is planned to work with the Employee details (full report).

After making any changes to the Web.config configuration file, you must restart the Cassini Service.