The Axxon PSIM section is used for Axxon PSIM advanced setup. The settings panel for the Axxon PSIM section is shown in the figure.

 

The parameters of the Axxon PSIM settings panel are described in the table.

No

Parameter name

Field type

Description

Representation

Default value

Value range

1

The Core IP address field with button. Is set on the Client

Type-in the value in the field/use the  button

Set the IP address of the Axxon PSIM server to which the psim_host.exe module is connected by default.
In case of pressing button, IP address of the local computer is set


IP address

127.0.0.1

Depends on net settings of the Server. In case of connection failure dialog window requiring IP address is displayed

2

Keyboard prefix 

Type-in the value in the field

Set the prefix for a special keyboard. When a button is pressed on this key-board the Axxon PSIM detects when the button was pressed on this very keyboard

Symbol

-

Usually, a tilde (~), code 126

The Logging subsystem group

3

Debug mode 

Dropdown list

Set the mode of the Axxon PSIM Debug window displaying


List of available modes of Debug window displaying

None


Disabled Debug window is not displayed

Debug 1Debug window is displayed  and a log-file containing recordings about modules errors is created

Debug 2Debug window is displayed and a log-file containing recordings about modules errors and alerts is created

Debug 3Debug window is displayed and a log-file containing recordings about all the modules events is created

Debug 4Debug window is displayed and a log-file containing recordings about all the modules events, and also additional menu that is individual for each module (used by programmers) are created

4

Log-storing time (hours)

Type-in the value in the field

Set the time of keeping log files

Sequence

48 hours

> 0

5

Counters logging time (sec)

Type-in the value in the field

Assigns the time interval in seconds for logging processor load, memory usage, and disk usage

Sequence

60

Positive whole numbers not less than 60 and zero. If the value 0 is specified, sensor data is not included in the log file

6

Save logs

Checkbox

Enables logs saving

Boolean type

Yes

Yes – logs are saved

No – logs are not saved

7

Redirect to debugger

Checkbox

Enables the debugger

Boolean type

None

Yes – the debugger is in use

No – the debugger is not in use

8

Maximum size (MB)

Type-in the value in the field

Defines the maximum size of RAM that log files can use. Log files are archived after that size is reached

Sequence

100 MB

>= 100

Values less than 100 Mb are ignored

The JPG and AVI files export path group

9

The Default (Axxon PSIM\Exp-ort)/Other switch

Set in the position

Set the folder for exported files from Axxon PSIM video archive



-

Default (Axxon PSIM\Export)


Default (Axxon PSIM\Export) – exported to the C:\Users\%current user name%\Documents\Axxon PSIM\export\ folder

Other – exported to the selected folder

10

The Other field with the button

Click the button/type-in the value in the field

Set the pathname to the folder, where files from video archive are to be exported when the switch is set in the Other position

Pathname

-

-

11

Open folder

Click the button

Opens the current folder to export the  files

-

-

-

12Record pathCheckbox

The checkbox forbids export catalogue change while exporting the archive period as well as exporting the archive from AviExport utility

Boolean typeNo

Yes – export catalogue change is forbidden

No – export catalogue change is allowed

No group

13

Receive uncompressed video

Checkbox

Enables receiving uncompressed video from the Server. As a rule is set on the Client

Boolean type

No

Yes – Client receives uncompressed video from the Server

No – Client receives compressed video from the Server


14

Event viewer over all windows

Checkbox

Enable displaying the Event viewer window over all windows

Boolean type

No

Yes – the Event viewer window is displayed over all windows

No – the Event viewer  window is displayed if a corresponding screen is selected

15

Only local protocol

Checkbox

Enables logging the events registered in the given computer to the Events protocol database.

Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section

Boolean type

No

Yes – events registered in the given computer are recorded to the Events protocol database

No – all required events are recorded to the Events protocol database


16Sort tree objects by IDCheckbox

Enables sorting of objects in the tree by identifier.

Note 1. If sorting by name is chosen, and there are numbers in the object name, then the objects will be sorted in alphabetical order. For example, an object with the name "115" will be above the object with the name "15", because in the name "115" the second number is 1, and in the name "15" the second number is 5.

Note 2. This key also affects the sorting of objects in the tree when adding the objects to a layer in the Map Editor utility

Boolean typeNo

Yes – objects in the tree are sorted by identifier

No – objects in the tree are sorted by name

17

Disable protocol

Checkbox

Disables events logging to the Event viewer database on this computer.

Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section

Boolean type

No

Yes – events are not logged to the Event viewer database

No – events are logged to the Event viewer database


18

Used memory dump

Checkbox

Enables logging .dmp file with a copy of main memory with incorrect shutting down at least one of the system modules to the Axxon PSIM root folder

Boolean type

No

Yes – memory dump is created

No – memory dump is not created

19

Support old scripts

Checkbox

Set the support of program tools in Axxon PSIM

Boolean type

No

Yes – both scripts and programs are supported

No – only scripts are supported


20

Time synchronization

Checkbox

Set time synchronization of all computers in the distributed system with system time of this computer. Time is automatically synchronized at midnight every 24 hours or when Axxon PSIM is started on the Server that is the source of time synchronization

Boolean type

No

Yes – synchronization is enabled

No – synchronization is disabled


21

Overlay in Event protocol

Dropdown list

Set the overlay mode for processing the video signals that can be viewed with the help of the Event protocol object

Names of overlay modes

Overlay 2

None – video signals are not processed by video card

Overlay 1 – Direct3D is used

Overlay 2 – DirectDraw is used

22

Application language

Dropdown list

Assigns the Axxon PSIM Software System's interface language

Names of installed languages

-

Depends on the set of installed languages. See Axxon PSIM Software System's interface language

  • No labels