To configure the Hikvision reader access plan settings, do the following:

  1. Go to the Hikvision 28X Reader object setup panel.
  2. Click on the Access plan setup button. The Reader access plan setup window opens.
  3. In the area (1), set the required access type.

    Note.

    The Sleep access type stands for the sleep mode. The reader is not operable in this mode.

    The Card + Pass access type means that you first need to swipe the card and then enter the password, only then the access is granted.

    The Card/Auth.Pass access type means that you can swipe the card OR enter the password to access.

  4. In column (2), select the day of the week, and using the mouse, set the time interval for this access type in the corresponding line in area (3).
  5. If necessary, adjust the time interval in area (4), where the left field indicates the beginning time, and the right field indicates the ending time of this time interval.
  6. Click OK (5) to save the settings.
  7. Click Apply (2).

The access plan settings of the Hikvision reader are now configured.