Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

On page:

Sensor status indication

Identification of the sensor symbol on the Map depends on the current operating mode and sensor status, as well as the type of intrusion sensor. The sensor is always in 2 states simultaneously, therefore its icon on the map blinks and changes once in a certain period. State icons for different sensor types are shown below. The state written to the dbo.STATES database is given in the dbo.state column.

Heat sensor:

Statedbo.stateSymbol on the Map
ArmedARMED

DisarmedDISARMED

AlarmALARMED

*

Alarm confirmedCONFIRMED

Connection lostDETACHED_DISARM

*

Normal (off)OFF

Active (on)ON


Glass
sensor:

Statedbo.stateSymbol on the Map
ArmedARMED

DisarmedDISARMED

AlarmALARMED

*

Alarm confirmedCONFIRMED

Connection lostDETACHED_DISARM

*

Normal (off)OFF

Active (on)ON


Ceiling
sensor:

Statedbo.stateSymbol on the Map
ArmedARMED

DisarmedDISARMED

AlarmALARMED

*

Alarm confirmedCONFIRMED

Connection lostDETACHED_DISARM

*

Normal (off)OFF

Active (on)ON


Window
sensor:

Statedbo.stateSymbol on the Map
ArmedARMED

DisarmedDISARMED

AlarmALARMED

*

Alarm confirmedCONFIRMED

Connection lostDETACHED_DISARM

*

Normal (off)OFF

Active (on)ON


Infrared
sensor:

Statedbo.stateSymbol on the Map
ArmedARMED

DisarmedDISARMED

AlarmALARMED

*

Alarm confirmedCONFIRMED

Connection lostDETACHED_DISARM

*

Normal (off)OFF

Active (on)ON


Smoke
sensor:

Statedbo.stateSymbol on the Map
ArmedARMED

DisarmedDISARMED

AlarmALARMED

*

Alarm confirmedCONFIRMED

Connection lostDETACHED_DISARM

*

Normal (off)OFF

Active (on)ON


Reed
sensor:

Statedbo.stateSymbol on the Map
ArmedARMED

DisarmedDISARMED

AlarmALARMED

*

Alarm confirmedCONFIRMED

Connection lostDETACHED_DISARM

*

Normal (off)OFF

Active (on)ON


Note

Reference «*» means that the image of the given symbol is blinking.

For a Sensor security device type with the Circuit closure operation mode, an alarm event is generated in case of the sensor closure.  For a Sensor security device type with the Circuit interruption operation mode, an alarm event is generated in case of the sensor interruption.

If the Sensor is armed, then the "Alarm" event is generated in case of the sensor on/off switch depending on the specified alarm mode (see Creating and configuring the Sensor system object). If the Sensor is disarmed, then the "Closed"/"Opened" events are generated correspondingly. If the connection between the Intellect and the sensor is lost, the "Connection lost" event will be generated.

Note.

When an alarm is registered by any sensor, connected through IP-device Samsung SNC-M300P, Sensor symbol with 1channel number is activated (the given IP device supports two connection channels of sensors).

Operations with sensor

The sensor is operated via the feature menu of the given sensor symbol shown on the Map.

The feature menu of the sensor is called up by a right mouse click on the corresponding sensor symbol.

The feature menu of the sensor provides access to various operating functions of the sensor.

Feature menu item

Function

Comments

Sensor No./Date and time of the latest status modification

Shows the identifier of the selected sensor in the program, the current status of the sensor, the date and time of the latest sensor status modification

See the Using sensors section




Arm

Arms the sensor

Confirm

Confirms alarm event registration by the sensor

Disarm

Disarms the sensor

  • No labels