The automatic connection to a failover node is configured by connecting to a single Server of the failover system cluster. To add a node to automatic connection, do as follows:

  1. Specify the Connection timeout parameter (1), which determines how long one must wait for a successful connection before considering the attempt to be unsuccessful. The default timeout value is 60 seconds, the maximum value is 5 minutes. When using this setting, automatic connection will attempt to connect immediately. If the connection fails, the Server will wait for a user-specified period of time (timeout) and retry the connection.

  2. Specify the maximum number of automatic connection attempts after the specified timeout (2).
    Specify the maximum number of automatic connection attempts after the specified timeout (2).
  3. Set the Discover cluster checkbox (3).
  4. Enter the IP address of any cluster Server (4) and click the >> button (5).
  5. Select from the list the node you want to add to automatic connection (6).
  6. Click the Add button (7).