This action checks recorded video from a specific camera or group of cameras for the specified period.
To configure this action, do as follows:
- Configure the conditions to start a macro (see Configuring filters for event-driven macros).
Select a camera or a group of cameras to check if there is a record in the archive (1).
Attention!
If the start of the macro was triggered by the activation of input or output (see Configuring start conditions for event-driven macros) that is not connected to any camera, you need to select a specific camera here. If you select a group of cameras or a camera that triggered the command, the action will not start.
- Select an archive where you want to check if recorded video is available (2). If you leave the field empty, all recorded video in this camera archives will be checked.
- Specify the depth of check (3). The check time period covers: [the time of the action start - (minus) the depth of the check; start time of the action].
- Select an action if the archive record for the specified period is found (4).
- Select an action if the archive records for the specified period are not found (5).
Note
If E-mail is selected as a reaction, then the target cameras will be indicated in the message (if a group of cameras was selected) for which there are no entries in the archive for the specified period.
You can also use two special purpose templates in the message:
- {failureRecordCheck}—failed check of a record in an archive (format: Server Name|Camera Name|Archive Name);
- {successRecordCheck}—successful check of a record in an archive (format: Server Name|Camera Name|Archive Name).
Attention! For the correct execution of the macro, synchronize the time across all Servers within the Axxon-domain.