Documentation for Axxon PSIM 2.0. Documentation for other versions of PSIM is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

The AxxonOne Manager hardware object is used to set up integration with Axxon One. Only one AxxonOne Manager can be created per Axxon PSIM server, so if you need integration with multiple Axxon One domains, you will need to use multiple Axxon PSIM servers.

On this page:

Creating AxxonOne Manager

  1. Go to the Hardware tab in the system settings.
  2. Right-click on the Computer object, and in the context menu that appears, select Create objectAxxonOne Manager.

    Note

    The Computer object should correspond to the Axxon PSIM Server which is selected for integration.

  3. The Number and Name fields will be filled in automatically, but you can edit them if needed.
  4. Click Apply.

As a result, three objects will be created: AxxonOne Manager, along with ONVIF Server and RTSP Server associated with it.

The ONVIF Server (AxxonOne Manager) and RTSP Server (AxxonOne Manager) objects are used to set up integration using the Axxon One Web Server and are created by default. There is no need to delete or configure them; they should remain as they are.

Configuring AxxonOne Manager

  1. Select the created AxxonOne Manager in the hardware tree (1), go to the Integration with Axxon One tab (2), and set the Enable checkbox (3).
  2. Enter the information of the Axxon One instance you are connecting to (4):
    FieldDescriptionDefault value
    AddressIP-address127.0.0.1
    PortPort for communication with Client (NativeBL port)20109
    Base portPort for operations within a domain20111
    Web portWeb Server port (HTTP port for failover server)80
    LoginAxxon One usernameroot
    PasswordAxxon One passwordroot
    If cloud connection is used for authorization in Axxon One, set the Cloud checkbox.

    Note

    The connection ports depend on the type of Axxon One installation (failover or not) and its settings. For more information, see the Axxon One documentation:

    Ports used by Axxon One

    Configuring the Server ports

    Ports used by the failover system

    Changing ports in the nodes of the failover system

  3. Click the Update button (5) to synchronize with Axxon One. This button initiates reading and updating the Axxon One configuration to retrieve information and send it to Axxon PSIM:

    Attention!

    Specifics of synchronization with Axxon One using the Update button:

    • After clicking the button, you must wait for the process to complete without taking any further actions. This ensures that the states of Axxon One objects are correctly transferred.
    • If the configuration of a running Axxon One Server was previously retrieved and during the next synchronization the server status is "off," the equipment state in Axxon PSIM will remain unchanged. This is done to prevent accidental configuration clearing, for example, if the Axxon One server is rebooting during synchronization.
    • If you enter data of a new Axxon One domain for synchronization, the data from the previously synchronized domain will be deleted. If synchronization is done with a server from the same domain, the data will remain.
    • The equipment list, which was already retrieved, will be synchronized between Axxon PSIM and Axxon One "on the fly." However, to obtain information about new equipment or changes in the Axxon One configuration, you should click the Update button again.
    • If you delete in Axxon PSIM devices and macros received from Axxon One (and they remain in Axxon One), they will be recreated in Axxon PSIM during the next synchronization.
    • Equipment objects retrieved from Axxon One are created in Axxon PSIM without configuration panels, as they can only be configured in Axxon One.
    • Macros are created without predefined conditions, but they can be configured if needed. For more information, see Working with macros and events received from Axxon One.

    The result of the synchronization will be displayed in the information fields Last successful synchronization and Status of last synchronization (6). If the synchronization was successful, the equipment received from Axxon One will appear in the equipment list, and the received macros will appear in the Macros list on the Programming tab.

  4. In the Node name drop-down list, select the Axxon One server, the cameras from which will be displayed in the Axxon One Monitor interface (7).

  5. In the Path field, specify the path to the previously installed Axxon One Client (see Pre-configuration of Axxon One), which will be used to launch the Axxon One Monitor interface object (8). The default path is: C:\Program Files\AxxonSoft\AxxonOne\bin\AxxonOne.exe.

    Attention!

    Note that this path must be the same on all computers where the Axxon One Client (AxxonOne.exe) is to be run. This means that the Axxon One Client must be pre-installed in the same folder on all computers.


  6. Click Apply.

Integration with Axxon One is complete.

Deleting Axxon One сonfiguration

To completely remove the integration with Axxon One configured as described above, do the following:

  1. Make sure that the last synchronization with Axxon One was successful (check the Last successful synchronization and Status of last synchronization fields). If necessary, click Update to synchronize.
  2. On the AxxonOne Manager settings panel, click Delete configuration button.
  3. A Delete configuration window will open. Click OK to confirm.

As a result, all equipment and macro lists associated with this integration will be deleted. If an Axxon One Monitor interface object was configured, its camera list will also be cleared accordingly.

  • No labels