You can filter the start of macros when a face is recognized by specifying the following clarifying parameters:

  1. Age—age of a person, the Age and gender parameter must be enabled, see Configuring the Face detector VA.
  2. Gendergender of a person, the Age and gender parameter must be enabled, see Configuring the Face detector VA. Value: 1female, 2male.
  3. TemperatureValuetemperature of a person, the Face Detection and Temperature Control must be configured, see Face Detection and Temperature Control with Mobotix M16 TR cameras.

To set the parameters that specify the conditions, do the following:

  1. Select the Faces: Specified triggering event in the start conditions.
  2. Click the button.
  3. Specify the required parameter in the corresponding field (1).

    Attention!

    The parameter is case-sensitive.

  4. In the Value (2) and Max value (3) fields, set the range of parameter values within which the macro starts. 

    Note

    Examples. 

    If you set the Age parameter in the range [18; 100], the macro starts only if the detection tool returns the age value of 18 or more.

    If you set the Gender parameter in the range [1; 1], the macro starts only if the detection tool returns the person's gender as female.

    If you set the Gender parameter in the range [2; 2], the macro starts only if the detection tool returns the person's gender as male.

    If you set the TemperatureValue parameter in the range [37; 100], the macro starts only if the detection tool returns the temperature value of 37 degrees or more.

  5. Specify one or more actions that must be performed (see Settings specific to actions).
  6. Click the Apply button.