To configure the action, do the following:
- Configure the conditions to start a macro (see Configuring filters for event-driven macros).
- Select a PTZ device that you want to use from the PTZ list (1). Any PTZ cameras can be used, including those from other Servers (if they are on).
- Select the preset (2) to which you want to switch when a macro is initiated.
- Set the rotation speed of the camera (3). The value must be in the range [1; 100].
Set the control priority of the camera (4). The priority determines the user with which access level (see Roles) will take over the control of the camera when the macro is running.
Set time (5). If the macro is running and the user has a lower access level than the macro, the user will be able to control the PTZ camera only after this time has elapsed.
Note
In order to create a sequential switching to specified presets at selected time intervals (5), set Wait till previous action finishes between the switching actions. You can also set Wait for timeout. In this case, the switching between the presets will take place after the timeout time.