To configure the Multiple Objects, do the following:
- Create the required detection tool and specify its parameters (see Configuring detectors and their sub-detectors).
- Below the created detection tool, click Create… → Multiple Objects.
By default, the detection tool is enabled and set to generate events when the number of objects in the detection area exceeds the value specified in the detection tool settings.
If necessary, you can change the detection tool parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Other | ||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value |
No | ||
Name | Multiple Objects | Enter the detection tool name or leave the default name |
Type | Multiple Objects | Name of the detection tool type (non-editable field) |
Basic settings | ||
Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100] Attention! The values of the maximum object height must be equal in the settings of the Object Tracker and Multiple Objects. |
Maximum object speed | 500 | Specify the maximum object speed per second for the detection tool to generate an event. The value must be in the range [0, 500] Note
|
Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100] Attention! The values of the maximum object width must be equal in the settings of the Object Tracker and Multiple Objects. |
Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100] Attention! The values of the minimum object height must be equal in the settings of the Object Tracker and Multiple Objects. |
Minimum object speed | 0 | Specify the minimum object speed per second for the detection tool to generate an event. The value must be in the range [0, 500] Note
|
Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detection tool to generate an event. The value must be in the range [0.05, 100] Attention! The values of the minimum object width must be equal in the settings of the Object Tracker and Multiple Objects. |
Number of alarm objects | 10 | Specify the number of objects for the detection tool to generate an event. The value must be in the range [1, 100]. |
Object class | All classes | Select the object class that must generate an event. The default value is All classes Note
|
Vehicle | ||
Person |
By default, the entire frame is a detection area. If necessary, in the preview window, you can reduce the detection area (see Configuring a detection area) and/or set one or more skip areas (see Configuring a skip area).
Note
- For convenience of configuration, you can "freeze" the frame. Click the button. To cancel the action, click this button again.
- The detection area is displayed by default. To hide it, click the button. To cancel the action, click this button again.
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button.