Setting the trap with SNMP-message is done in the following way:

  1. Go to the settings panel of SNMP trap system object.
  2. In the IP field, enter IP-address from SNMP-manager, that will receive SNMP-traps with messages concerning the events (1).
  3. In the field Group, enter the community name for SNMP-trap authentication on the computer with installed SNMP-manager(2).

    Note.

     Safety model on the basis of communities is realized in Axxon PSIM program complex.
  4. In the field Variable OID, enter the unique trap’s number in the tree of SNMP-objects (3).
  5. To save the changes click Apply button (4).

Setting up the trap with SNMP-message is completed.