To configure the CORTEX WinSC integration module, do the following:
- Go to the settings panel of the CORTEX WinSC object.
- In the Address field, specify the address of the computer to connect the CORTEX Security Commander to the Axxon One + ACFA server.
- In the Port field, specify the number of the port to connect the CORTEX Security Commander to the Axxon One + ACFA server. The default value is 3023.
- In the Command timeout field, specify in seconds the period during which the CORTEX controller waits for commands. The default value is 3.
- In the Default event settings field:
- In the Event 0 field, specify the event value from the CORTEX Security Commander.
The default value is E. - In the Event 1 field, specify the event value from the CORTEX Security Commander.
The default value is R.
- In the Event 0 field, specify the event value from the CORTEX Security Commander.
- In the Object count field, specify the number of the objects created in the system when downloading the configuration. The default value is 1.
- Click the Apply button to save the changes.
- Click the button and select Download configuration from the drop-down list to download the configuration automatically and build the device tree.
- Click the Apply button.
Configuration of the CORTEX WinSC integration module is complete. As a result, a device tree is built.