Configuring the Axxon PSIM Biometric Identification server is required if the controller/terminal is configured for the Server identification system mode (see Configuring the BioSmart UniPass controller and Configuring the BioSmart PV-WTC terminal).
Attention!
The Axxon PSIM Biometric Identification server works only with the BioSmart UniPass and BioSmart PV-WTC controllers.
To configure the Axxon PSIM Biometric Identification server, do the following:
- Go to the settings panel of the BioSmart parent object.
- In the Identification server group, select Yes from the Use drop-down list (1).
- In the Local IP field (2), enter the local IP address of the Axxon PSIM Biometric Identification server.
- In the Local port field (3), select the local port number of the Axxon PSIM Biometric Identification server.
From the Matching accuracy drop-down list (4), select the matching accuracy of the palmprint and the palmprint stored in the controller/terminal: Maximum (default), High, Normal, Low, Lower, Minimum.
Note
The higher the matching accuracy, the longer it takes to check the matching of the palmprint, but the security is higher.- Set the Anti-fake checkbox (5) to enable protection of biometric readers from bringing objects other than the palm of the hand (so that the controller does not react, for example, on palm photo).
- Click the Apply button to save the changes.
Configuration of the Axxon PSIM Biometric Identification server is complete.