Documentation for Axxon PSIM 2.0. Documentation for other versions of Axxon PSIM is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

Attention!

For full operation of the settings of the User object, we recommend installing the Access Manager module as part of the ACFA PSIM subsystem (for details, see ACFA PSIM Installation Guide. IntroductionGuide for configuring and working with the Access Manager module). If you installed the Access Manager module, the values of the fields will be synchronized.

You can use the settings of the User object to configure the access control system.

The Access control tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the User object in the system

Digits, letters, periods, hyphen, dash and underscore

NA

Depends on the number of the User objects in the system

2

Name*

Enter the value into the field

Sets the name of the User object in the system (usually the user's last name)

Latin alphabet, Cyrillic alphabet, and service characters

User 

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of characters—from 1 to 60.

Do not enter rs in this field when registering Operator accounts, as this value is used as a default username in Axxon PSIM Web Report System

3

Disable

Set the checkbox

Enables the function of deactivating the User object in the system

Boolean type

Clear

Set—the User object is disabled and isn't used

Clear—the User object is enabled and used

4

Department

Select the value from the list

Sets the Department parent object for the given User object

Names of the Department objects registered in the system

Name of the Department parent object

Depends on the number of the Department objects in the system

5NameEnter the value into the fieldSets the user's nameLatin alphabet, Cyrillic alphabet, and service charactersNAA line containing a sequence of any characters
6PatronymicEnter the value into the fieldSets the user's patronymicLatin alphabet, Cyrillic alphabet, and service charactersNAA line containing a sequence of any characters
7PhoneEnter the value into the fieldSets the user's phone number for the two-factor authenticationPhone numberNA+ [country code][city code][subscriber number]
For example, +11234567890
8AD connectionClick the buttonOpens a window to configure the connection between the Axxon PSIM user and the Windows Active Directory userNANANA
9AD connection AutomaticallyDisplays the Active Directory user identifier connected with the Axxon PSIM userLatin alphabet and service charactersNADepends on the values of Active Directory identifiers
10Additional infoEnter the value into the field

Specifies additional information about the user.

When you hover the mouse cursor over the user's photo, a pop-up window with the full content of this field is displayed

Latin alphabet, Cyrillic alphabet, and service charactersNAA line containing a sequence of any characters
11User lockedSet the checkboxEnables the function of locking the User object in the systemBoolean typeClear

Set—the User object is locked

Clear—the User object is active

12

Antipassback


Set the checkbox

Enables the function of antipassback

Boolean type

Clear.

Note. If you have the Access Manager module installed, the default value will depend on the module settings (see Configuring the rights to manage objects in Access Manager

Set—Antipassback is prohibited

Clear—Antipassback is allowed

13

Object code

Enter the value into the fieldSets the Object code of the access controlLatin alphabet, Cyrillic alphabet, and service charactersNA

A line containing a sequence of any characters.

Note. If you have the Access Manager module installed, the value range will depend on the module settings (see Configuring access cards)

14Permanent cardEnter the value into the fieldSets the number of the permanent card of the User objectLatin alphabet, Cyrillic alphabet, and service charactersNA
15Temporary cardEnter the value into the fieldSets the number of the temporary card of the User objectLatin alphabet, Cyrillic alphabet, and service charactersNA
16

Valid till


Enter the value into the fieldSets the date after which the validity of the temporary card of the User object is limited

Digits and service characters.

Date in the format:

  • DD mmm YYYYY;
  • HH:MM:SS
NANA
17PINEnter the value into the field

Sets the PIN code of the user card

Latin alphabet, Cyrillic alphabet, and service charactersNA

A line containing a sequence of any characters.

Note. If you have the Access Manager module installed, the value range will depend on the module settings (see Configuring the user PIN code)

The Additional cards table
18Object codeEnter the value in the columnSets an additional Object code of access controlLatin alphabet, Cyrillic alphabet, and service charactersNA

A line containing a sequence of any characters.

Note. If you have the Access Manager module installed, the value range will depend on the module settings (see Configuring access cards)

19CardEnter the value in the columnSpecifies an additional card code of access controlLatin alphabet, Cyrillic alphabet, and service charactersNA

*The name of the element isn’t displayed on the settings panel of the object.

The Access Levels tab

ParameterMethod of setting the parameter valueParameter descriptionRepresentationDefault valueValue range
20Access typeSelect the value from the listSets the Access type for the userList of access types

Group

 

  • Group
  • Access forbidden; 
  • Full access;
  • List.

If you set the Group access level, the user is assigned the access level of the department to which they belong

21A.L.**Select the value from the listSets the user's Access LevelList of access typesNANA
22Date1**Automatically

Displays the start date of the temporary Access Level.

Format: DD.MM.YYYY

Digits and service characters except: < | >

NANA
23Time1**Automatically

Displays the start time of the temporary Access Level.

Format: HH:MM:SS

Digits and service characters except: < | >

NANA
24Date2**Automatically

Displays the end date of the temporary Access Level.

Format: DD.MM.YYYY

Digits and service characters except: < | >

NANA
25Time2**Automatically

Displays the end time of the temporary Access Level.

Format: HH:MM:SS

Digits and service characters except: < | >

NANA
26Photo area*Automatically

Displays a photo of the User object

Graphical representationNANA

Note

Using the Access Manager module as part of the ACFA PSIM subsystem (see Guide for configuring and working with the Access Manager module), you can specify the photo displayed on the settings panel of the User object. You can also add or change the user's photo using the Face recognition and search module that is a part of Face PSIM (for details on how to configure and work with this module, see Face PSIM documentation in the AxxonSoft documentation repository).

*The name of the element isn’t displayed on the settings panel of the object.

** To change these parameters, you can use the Access Manager module as part of the ACFA PSIM subsystem (see Assigning a temporary access level to a user).

  • No labels