The settings panel of the Monitor object is shown in the figures.

The Basic settings tab

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Monitor interface object in the system

Numbers, letters, periods, hyphen, dash, and underscore

NA

A line containing numbers, letters, periods, hyphen, dash, and underscore

Depends on the number of the Monitor objects in the system

2

Name*

Enter the value in the field

Sets the name of the Monitor object in the system

Latin, Cyrillic, numbers and service characters

Monitor

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Disables the Monitor object in the system

Boolean type

Clear

Setthe Monitor object is disabled and isn't used

Clearthe Monitor object is enabled and used

4

Display

Select the value from the list

Sets the Display parent object for the given Monitor object

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the system

The Coordinates group

5

X

Enter the value in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the Monitor interface window

% of the screen width

60

From 0 to M*100, where M is the number of the installed computer monitors

6

Y

Enter the value in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the Monitor interface window

% of the screen height

50

From 0 to M*100, where M is the number of the installed computer monitors

7

W

Enter the value in the field

Sets the width of the Monitor interface window

% of the screen width

40

From 20 to 900 if control panel is enabled. Otherwise, from 0 to 900.

This restriction can be disabled using the UnlimitMonitorSize registry key (see Registry keys reference guide)

8

H

Enter the value in the field

Sets the height of the Monitor object if the control panel is disabled

% of the screen width

40

From 0 to 900.

This restriction can be disabled using the UnlimitMonitorSize registry key (see Registry keys reference guide)

9

Monitor

Select the value from the list

Sets the number of the physical monitor, the coordinates for which are set. The monitors are numbered in the order of their physical location from left to right, from top to bottom. The 1st monitor is the one in the upper left corner regardless of which monitor is set as main or what number the monitor has in OS.

In the figure below, the monitor numbers in OS are given in gray while the numbers in Axxon PSIM are red.

Attention!

We recommend setting the same resolution for all monitors in the system. Different resolution is only allowed if all monitors are aligned along any border (for example, upper border)

Sequence of numbers

1

From 1 to 16

10

Allow moving

Set the checkbox

Allows moving the the Monitor interface window manually, if the control panel is enabled

Boolean type

Clear

Set—the manual moving is allowed

Clear—the manual moving isn't allowed

11

The  button

Click the buttonOpens the window for specifying the position and size of the Monitor interface windowNANANA
The Quad splitter group
12horizontalEnter the value in the field

Sets the number of the surveillance windows that must be displayed horizontally on the Monitor. If the value isn't specified (the field is blank), then the default grid of the surveillance windows depending on the selected layout is displayed

Sequence of numbersBlank fied

From 1 to 64.

Blank fied—the default grid of the surveillance windows depending on the selected layout is displayed

13verticalEnter the value in the field

Sets the number of the surveillance windows that must be displayed vertically on the Monitor. If the value isn't specified (the field is blank), then the default grid of the surveillance windows depending on the selected layout is displayed

Sequence of numbersBlank fied

From 1 to 64.

Blank fied—the default grid of the surveillance windows depending on the selected layout is displayed

The Basic settings tab

14

Display

Select the value from the list

Sets the mode for processing the video signals from the cameras by the graphics card

Names of the display modes

Opengl

  • Opengl is selected by default. This mode uses the most advanced Windows graphics libraries for rendering 2D and 3D graphics;
  • Direct3D is the recommended mode that uses the most advanced Windows graphics libraries. Use this mode when it is necessary to display the video from the fisheye cameras or the signal decoded using Intel QuickSync technology
  • DirectDraw is used if the graphics card doesn't support Direct3D;
  • Softwarevideo signals aren't processed by the graphics card. It is used if Axxon PSIM is installed on a virtual platform

15


Active camera

Sets in the position

Sets the display mode for an active camera window only

Boolean type


Clear

Setthe Active camera mode is enabled and used

Clear—the Active camera mode is disabled and isn't used

Alarm cameras

Sets the display mode for alarm cameras windows

Clear

Setthe Alarm cameras mode is enabled and used

Clear—the Alarm cameras mode is disabled and isn't used

List

Sets the display mode of the camera windows according to the selected layout

Set

Set—the List mode is enabled and used

Clearthe List mode is disabled and isn't used

16

Control panel

Set the checkbox

Enables the display of the toolbar on the Monitor in the List mode

Boolean type

Clear

Setthe control panel is enabled and used

Clearthe control panel is disabled and isn't used

17

Use button attached to camera

Set the checkbox

Enables the display of the Button objects attached to Cameras in the Surveillance windows

Boolean type

Clear

Set—Buttons are displayed in the Surveillance windows

Clear—Buttons aren't displayed

18

Max

Enter the value in the field

Sets the maximum number of the cameras windows that can be simultaneously displayed on the Monitor in the Alarm cameras and List modes. If the number of alarm cameras is greater than the maximum number, the Monitor will display the number of cameras specified in the Max field

Sequence of numbers

NA

>0

Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras

19

Min

Enter the value intthe field

Sets the minimum number of video cameras windows that can be displayed on the Monitor in the Alarm camers mode. If the number of the alarm cameras is less than the minimum number, the Monitor will display fewer cameras than specified in the Min field. At the same time, the Monitor fold will remain consistent with the Min field

An integer from zero and greater (for example, 0, 2, 50)

NA

>=0

Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras.

0—when there are no alarms, the camera windows aren't displayed in the Monitor window

20

Keep camera ratio

Set the checkbox

Sets the ratio of the width and height of the video image in the surveillance windows on the Video surveillance monitor

Boolean type

Clear

Setthe ratio of the width and height of the video image corresponds to the ratio of the camera

Clearvideo image fits the entire area of the Surveillance window, while the ratio may be affected

21

Show captions

Set the checkbox

Shows the captions for the cameras of the Monitor interface window.

In large distributed systems, we recommend disabling captions on those monitors where you don't want to show captions.

This checkbox also affects the display of frames around detected objects or abandoned objects (see Smart video detection tools operation) when viewing archive:

Boolean type

Set

Setthe Captions submenu is available in the context menu of the Monitor interface window, captions are displayed. The frames generated by the VMDA smart video detectors are displayed

Clearthe Captions submenu is unavailable in the context menu of the Monitor interface window, captions aren't displayed. The frames generated by the VMDA smart video detectors aren't displayed

22

Smoothing

Set the checkbox

It is used when it is required to display video with greater resolution on which the ladder effect appears when displaying in the small window.

Note. When this feature is enabled, the CPU load of the computer where the display is performed increases. We recommend displaying video from analog cameras or low-resolution video only

Boolean type

Clear

Setsmoothing is applied

Clearsmoothing isn't applied

23

PTZ control

Select the value from the list

Sets the priority to control the PTZ devices using the Monitor object

Names of the PTZ devices control priorities

Low priority

  • Forbidden—the option of the PTZ control using the Monitor object is disabled;
  • Low prioritylow priority of control;
  • Normal priority—medium priority of control;
  • High priorityhigh priority of control

24

Slideshow

Enter the value in the field

Sets the period of the automatic slideshow of the camera windows when the control panel is enabled

Period in seconds (s)

Blank field

Blank field or 0the camera windows are scrolled every 3 seconds

An integer from 1 to 600the camera windows are scrolled at the specified interval

25

Audio player

Select the value from the list

Sets the Audio player object used to playback the audio signals and export video recordings with audio from the Monitor interface

Names of the Audio player objects registered in the system

NA

Depends on the number of the Audio players registered in the system

26

Select camera with grouping and search

Set the checkbox

Enables a dialog window for switching a camera in the Surveillance window in which cameras are grouped by Computer, and you can search them by their name (see Selecting camera to display in Surveillance window)

Boolean type

Set

Set—to switch to another camera, a special dialog window opens, in which cameras are grouped and there is a search line

Clear—camera is selected in the function menu of the Surveillance windows without opening a special dialog window

27Group of checkboxes used to display the elements of the Surveillance windows Set the checkboxesAllows enabling and disabling the display of various elements of the Surveillance window such as number, name, time, menu, camera frame and additional info on the camera, as well as the name of Video surveillance monitorBoolean typeAll checkboxes are set except Additional info

Setthe corresponding element is displayed in the Surveillance windows of all cameras added to the Video surveillance monitor

Clearthe corresponding element isn't displayed in the Surveillance windows on the Video surveillance monitor

 *Name of the element isn't displayed in the settings panel of the given object.

The List of cameras tab

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Number

Select the value from the list

Sets the number of the camera to display on the Monitor

Sequence of numbers

NA

Depends on the number of the cameras registered in the system

Camera

Select the value from the list

Sets the name of the video camera to display on the Monitor

Name of the cameras registered in the system

NA

Depends on the number of the cameras registered in the system

Video stream

Select the value from the list

Sets the number of the video stream displayed from the camera when connected directly. If connected via the server, this setting doesn't affect anything

Numbers of the video streams

Default

1, 2, 3, 4video streams numbers

Defaultdefault video stream

Connection 

Select the value from the list

Sets the way of receiving video image from the camera

Ways of receiving video

Through server

Directthe video stream is received directly from the camera

Through serverthe video stream is received from the server, to which the camera is connected

fps

Select the value from the list

Sets the FPS for transmitting the video signal to the Client Monitor

Sequence of numbers

Blank field

1, 2, 3, 4, 6, 8, 12, 16, 20, 25, 30

Blank fieldfps value from the camera settings

Hardware decoding

Select the value from the list

Sets the hardware decoder of the video signal. Selecting a hardware decoder increases the load on the corresponding CPU

List of available decoders

Blank field 

  • Blank field (default CPU decoder),
  • Nvidia decoder,
  • Intel Quick Sync

Compression

Select the value from the list

Sets the compression level for transmitting the video signal to the client Monitor. The given value leads to extra consumption of server resources

Sequence of numbers

NA

In the order of increasing the compression level from 0 to 5.

0the video signal isn't compressed

5maximum compression of the video signal

Compressor

Select the value from the list

Sets the algorithm for the video stream compression which is used for the video signal recompression when displaying on the Monitor. If you set the compressor, it is necessary to set the value in the Compression list

List of available algorithms

NA

  • MJPEG,
  • Motion Wavelet 3.5,
  • MPEG4

Gate

Select the value from the list

Sets the Videogate object via which the live and archive video from the selected camera must be transmitted to the Monitor

Names of the Videogate objects registered in the system

NA

Depends on the number of the Videogate objects registered in the system

Backup archive

Select the value from the list

Sets the Backup archive object from which the video archive from the selected camera must be transmitted to the Monitor

Names of the Backup archive objects registered in the system

NA

Depends on the number of the Backup archive objects registered in the system

Edge storage

Select the value from the list

Sets the Edge storage object from which the video archive must be transmitted to the Monitor via the selected camera

Names of the Edge storage objects registered in the system

NA

Depends on the number of the Edge storage objects registered in the system

Gateway for Backup archive

Select the value from the list

Sets the Videogate object via which the video archive of the Backup archive object must be transmitted to the Monitor

Names of the Videogate objects registered in the system

NA

Depends on the number of the Videogate objects registered in the system

VMDA metadata storageSelect the value from the listSets the VMDA metadata storage object used for the forensic search in the archive of the corresponding cameraNames of the VMDA metadata storage objects registered in the systemNADepends on the number of the VMDA metadata storage objects registered in the system
Type of displaySelect the value from the listSets the type of conversion performed in the Surveillance window on the Video surveillance monitorSupported conversion typesPTZ

PTZvirtual telemetry

Panoramapanoramic view

Macro1Select the value from the listSets the first macro to be displayed in the function menu of the camera in the Surveillance windowNames of the Macro objects registered in the systemNADepends on the number of the Macro objects registered in the system
Macro2Select the value from the listSets the second macro to be displayed in the function menu of the camera in the Surveillance windowNames of the Macro objects registered in the systemNADepends on the number of the Macro objects registered in the system
GuidAutomaticallyDisplays the unique identifier of the camera in the systemSequence of numbers, Latin and service charactersNAA line containing a sequence of any characters (letters, digits, service characters) enclosed in {curly brackets}

2

Range

Click the button

Opens the Addi/ Edit cameras window and appears the access to complex selection and editing of cameras parameters for displaying on the Monitor

NA

NA

NA

3

All

Click the button

Selects all cameras registered in the system for displaying on the Monitor

NA

NA

NA

4

Automatic selection of streams for display

Set the checkbox

Enables the function of automatic selection of video stream for displaying on the Monitor. Affects cameras for which the On default video stream is selectedsee item 28

Boolean type

Clear

Setvideo stream for display is selected depending on the size of the video image on the Monitor and the required frame frequency

Clearvideo stream is selected depending on the Video stream and Connection settings and on the settings of the server and camera from which the stream is required

The PTZ tab

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

The Mouse group

1

Mouse Behavior

NA

The list of available actions with a mouse

NA

NA

NA

2

Action

Select the value from the list

Sets the reaction performed when executing the corresponding action with a mouse

Reaction list of the PTZ device object

(Default)

Reaction list of the PTZ device object

3

Param.

Enter the value in the field

Sets the value of the reaction parameter if it’s required

Depends on the selected action

NA

Depends on the selected reaction. For the reactions connected with the presets, it is a preset number. For other reactions, it is speed if the selected reaction allows specifying speed as a parameter. If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the Camera seleected on the Monitor, is used

The Joystick group

4

Butt.

NA

List of joystick buttons

NA

NA

NA

5

Action

Select the value from the list

Sets the reaction which must performed when clicking the joystick button

List of reaction of the PTZ device object

(Default)

List of reaction of the PTZ device object


6

Param.

Enter the value in the field

Sets the value of the reaction parameter if it is required

Depends on the selected action

NA

Depends on the selected reaction. For the reactions connected with the presets, it is a preset number. For other reactions, it is speed if the selected reaction allows specifying speed as a parameter. If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the Camera seleected on the Monitor, is used

The Interface tab

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

AlarmSelect the color

Sets the frame color of the Surveillance window in the alarm state

RGB colorsRedRGB color palette
ArmedSelect the color

Sets the frame color of the Surveillance window when the camera is armed

RGB colorsYellowRGB color palette
DisarmedSelect the colorSets the frame color of the Surveillance window when the camera is disarmedRGB colorsGreenRGB color palette
No frame Select the colorSets the frame color of the Surveillance window when there is no frame in itRGB colorsBlackRGB color palette
No signalSelect the colorSets the frame color of the Surveillance window when there is no signal from the cameraRGB colorsGreyRGB color palette
Screen cacheSelect the colorSets the Surveillance window background color that is displayed when the video from the camera doesn't cover completely the Surveillance window, for example, when the camera proportions are maintainedRGB colorsPurpleRGB color palette
Tracker frame color Select the colorSets the frame color to highlight the tracking objects on the video imageRGB colorsWhiteRGB color palette
2DefaultClick the button

Sets the default frame colors of the Surveillance window

NANANA
3Hide capture framesSet the checkboxHides the frames displayed by the Face detection module when a person’s face is detected on the video imageBoolean typeClear

Setthe Face detection frames aren't displayed

Clearthe Face detection frames are displayed

4Over all windowsSet the checkboxEnables the display of the Video surveillance monitor on top of all windowsBoolean typeClear

Setthe Video surveillance monitor is displayed on top of all windows

Clearthe Video surveillance monitor is displayed in the default mode

  • No labels