Go to documentation repository
Previous page Next page
Attention!
For full operation of the settings of the User object, we recommend installing the Access Manager module as part of the ACFA PSIM subsystem (for details, see ACFA PSIM Installation Guide. Introduction, Guide for configuring and working with the Access Manager module). If you installed the Access Manager module, the values of the fields are synchronized.
You can use the settings of the User object to configure the access control system.
The table describes the main setting parameters of the User system object.
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the User system object in the system | Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the User objects in the system |
2 | Name* | Enter the value in the field | Sets the name of the User object in the system (usually the user's last name) | Latin alphabet, Cyrillic, digits, and service characters | User | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60. Do not enter "rs" in this field when registering Operator accounts, as this value is used as a default username in Axxon PSIM Web Report System |
3 | Disable | Set the checkbox | Disables the User object in the system | Boolean type | Clear | Set—the User object is disabled and isn't used Clear—the User object is enabled and used |
4 | Department | Select the value from the list | Sets the Department parent object for the given User object | Names of the Department objects registered in the system | Name of the Department parent object | Depends on the number of the Department objects in the system |
5 | Name field | Enter the value in the field | Sets the user's name | Latin alphabet, Cyrillic, and service characters | NA | A line containing a sequence of any characters |
6 | Patronymic field | Enter the value in the field | Sets the user's patronymic | Latin alphabet, Cyrillic, and service characters | NA | A line containing a sequence of any characters |
7 | Phone | Enter the value in the field | Sets the user's phone number for the two-factor authentication | Phone number | NA | + [country code][city code][subscriber number]
|
8 | AD connection button | Click the button | Opens a window to configure the connection between the Axxon PSIM user and the Windows Active Directory user | NA | NA | NA |
9 | AD connection field | Automatically | Displays the Active Directory user identifier connected with the Axxon PSIM user | Latin alphabet and service characters | NA | Depends on the values of Active Directory identifiers |
10 | Additional info field | Enter the value in the field | Specifies additional information about the user. When you hover the mouse cursor over the user's photo, a pop-up window with the full content of this field is displayed | Latin alphabet, Cyrillic, digits, and service characters | NA | A line containing a sequence of any characters |
11 | User locked field | Set the checkbox | Enables the function of locking the User object in the system | Boolean type | Clear | Set—the User object is locked Clear—the User object is active |
12 | Antipassback | Set the checkbox | Enables the function of antipassback | Boolean type | Clear. Note. If you have the Access Manager module installed, the default value will depend on the module settings (see Configuring the rights to manage objects in Access Manager) | Set—Antipassback is prohibited Clear—Antipassback is allowed |
13 | Object code | Enter the value in the field | Sets the Object code of the access control | Latin alphabet, Cyrillic, digits, and service characters | NA | A line containing a sequence of any characters, letters, and digits Note. If you have the Access Manager module installed, the value range will depend on the module settings (see Configuring access cards) |
14 | Permanent card field | Enter the value in the field | Sets the number of the permanent card of the User object | Latin alphabet, Cyrillic, digits, and service characters | NA | |
15 | Temporary card field | Enter the value in the field | Sets the number of the temporary card of the User object | Latin alphabet, Cyrillic, digits, and service characters | NA | |
16 | Valid till | Enter the value in the field | Sets the date after which the validity of the temporary card of the User object is limited | Digits and service characters. Date in the format:
| NA | NA |
17 | PIN field | Enter the value in the field | Sets the PIN code of the user card | Latin alphabet, Cyrillic, digits, and service characters | NA | A line containing a sequence of any characters. Note. If you have the Access Manager module installed, the value range will depend on the module settings (see Configuring the user PIN code) |
The Additional cards table | ||||||
18 | Object code column | Enter the value in the column | Sets an additional Object code of access control | Latin alphabet, Cyrillic, digits, and service characters | NA | A line containing a sequence of any characters. Note. If you have the Access Manager module installed, the value range will depend on the module settings (see Configuring access cards) |
19 | Card column | Enter the value in the column | Specifies an additional card code of access control | Latin alphabet, Cyrillic, digits, and service characters | NA |
*The name of the element isn’t displayed on the settings panel of the object.
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
20 | Access type drop-down list | Select the value from the list | Sets the Access type for the user | List of access types | Group
|
If you set the Group access level, the user is assigned the access level of the department to which they belong |
21 | A.L.** drop-down list | Select the value from the list | Sets the user's Access Level | List of access types | NA | NA |
22 | Date1** field | Automatically | Displays the start date of the temporary Access Level. Format: DD.MM.YYYY | Digits and service characters except: < | > | NA | NA |
23 | Time1** field | Automatically | Displays the start time of the temporary Access Level. Format: HH:MM:SS | Digits and service characters except: < | > | NA | NA |
24 | Date2** field | Automatically | Displays the end date of the temporary Access Level. Format: DD.MM.YYYY | Digits and service characters except: < | > | NA | NA |
25 | Time2** field | Automatically | Displays the end time of the temporary Access Level. Format: HH:MM:SS | Digits and service characters except: < | > | NA | NA |
26 | Photo area* | Automatically | Displays a photo of the User object | Graphical representation | NA | NA |
Note
Using the Access Manager module as part of the ACFA PSIM subsystem (see Guide for configuring and working with the Access Manager module), you can specify the photo displayed on the settings panel of the User object. You can also add or change the user's photo using the Face recognition and search module that is a part of Face PSIM (for details on how to configure and work with this module, see Face PSIM documentation in the AxxonSoft documentation repository).
*The name of the element isn’t displayed on the settings panel of the object.
** To change these parameters, you can use the Access Manager module as part of the ACFA PSIM subsystem (see Assigning a temporary access level to a user).
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
27 | Login field | Automatically | Displays the Login of the user | Latin alphabet, Cyrillic, digits, and service characters | NA
| A line containing a sequence of any characters |
28 | Authorization parameters button | Press the button | Opens a window to change login and password | NA | NA | NA |
29 | Windows authorization checkbox | Set the checkbox | Enables Windows authorization option | Boolean type | Clear | Set—Windows authorization is used Clear—Windows authorization isn't used |
30 | User drop-down list | Select the value from the list | Selects the user from the list | The list of User objects registered in the system | NA | Depends on the number of User objects in the system |
31 | Change password on first access checkbox | Set the checkbox | Changes password on the first access | Boolean type | Clear | Set—change password on the first access Clear—don't change password on the first access |
32 | Change password every _ months checkbox | Set the checkbox | Changes password every _ months Note. If you set the Change password every _ months checkbox, the Change password on first access checkbox is set automatically | Boolean type | Clear | Set—change password every _ months Clear—don't change every _ months |
Change password every _ months field | Enter the value in the field | Sets a certain number of months after which you must change the password | Integer numbers | 0 (not specified) | >=0 | |
33 | Allow password change by user checkbox | Set the checkbox | Changes password by user's request | Boolean type | Clear | Set—change password by user's request Clear—don't change password by user's request |
34 | Supervisor drop-down list | Select the value from the list | Sets the Supervisor that confirms the authorization of another user in the system. For more details, see Starting and shutting down the Axxon PSIM software | The list of User objects registered in the system | NA | Depends on the number of User objects in the system |
*The name of the element isn’t displayed on the settings panel of the object.