Setting up the TREZOR-B04 and TREZOR-R channel is performed in the following way:
Specify the amplification weight in the LF channel path (from 0 to 5) for the ATA parameter (2). The ‘0’ ATA numeric value is conventional and designates the absence of this option.
The ATA option works only if the Working mode has the LF value. |
Specify the True value for the Armed parameter (5), if required, so as this channel is armed. Set the False value in order to make the channel inactive (disarmed).
The Armed parameter can be set using the Map interactive window. For more details see Operating the TREZOR-B04 and TREZOR-R channel. |
From the Preset drop-down list (8), select the preset for the initial selection of groups of numerical values of all parameters of the signal processing algorithm for the LF channel.
The preset is the aggregated sets of parameter numeric values which are saved in the device processing algorithm proceeding from the Signaling Fence type. |
There are 8 presets:
Preset | Description |
---|---|
Factory | The initial set of algorithm parameter numeric values |
SSCP cloth | The set of algorithm parameter numeric values for the standard full-height Signaling Fence represented by welded wire mesh with a rod 1-6 mm in diameter. |
SSCP razor wire | The set of algorithm parameter numeric values for the standard Razor Wire Signaling Fence (1,2 m in height) represented by welded wire mesh with a rod 1-6 mm in diameter. |
AKL cloth | The set of algorithm parameter numeric values for the standard full-height Signaling Fence represented by flat razor wire (AKL). |
AKL razor wire | The set of algorithm parameter numeric values for the standard full-height Signaling Fence represented by cross razor wire (AKL). |
Profiled sheeting | The set of algorithm parameter numeric values for the standard Signaling Fence represented by profiled metal sheet. |
Wire mesh | The set of algorithm parameter numeric values for the standard Signaling Fence represented by wire mesh. |
Underground | The set of numeric values when blocking undermine under fence and setting the Shielded Sensor Cable (SSC) in the ground. |
The preset parameter values (see the The presets table) are not guaranteed to be optimum, however they allow to simplify the configuring process and require some correction when customizing for a certain type of Signaling Fence on the device application place. |
The Preset option works only if the Working mode has the LF value. |
Specify the time interval value for the Count interval parameter (9) in the range of 2 to 60 seconds in which the count of valid signal permitted impulses is performed.
The Count interval and Count parameters are interrelated. When increasing the Count interval parameter value one should increase the Count parameter value. |
Specify the permitted minimum interval between the two valid signal impulses for the Pause parameter (10) in the range of 40 to 400 milliseconds. If the set up pause is not maintained, the second received impulse following by the first one allowed does not count.
The Impulse and Pause parameters are interrelated, their meanings should not differentiate more than twofold. |
From the Rejection (LF) drop-down list (11), select the value of LF channel amplitude-frequency characteristic suitable rejection frequency. There are 18 rejection frequency values (in the decade band from 0 to 4,5 Hz). The ‘0 Hz’ rejection frequency numeric value is conventional and means the absence of this option.
The Rejection (LF) option works only if the Working mode has the LF value. |
From the Sawing duration drop-down list (12), select the time interval in the range of 1 to 15 sec; when it is exceeded, the alarm on sawing will be initialized.
The Sawing duration option works only if the Working mode has the HF value. |
The TREZOR-B04 and TREZOR-R channel setting has been finished.