The presets table of signal processing algorithm in LF-channel is not used for HF-channel.
Parameters | Type of lockable obstruction | |||||||
---|---|---|---|---|---|---|---|---|
SSCP cloth | SSCP razor wire | AKL cloth | AKL razor wire | Profiled sheeting | Wire mesh | Underground | Factory | |
Impulse ( duration is at least ) ms | 120 | 120 | 120 | 160 | 120 | 160 | 280 | 120 |
Pause ( duration is at least ) ms | 160 | 160 | 160 | 160 | 120 | 160 | 200 | 160 |
Window, sec | 10 | 8 | 10 | 8 | 10 | 10 | 4 | 10 |
Count (the amount of counting impulses) | 4 | 3 | 3 | 3 | 4 | 4 | 2 | 4 |
Alarm, sec ( duration is at least ) ms | 3 | |||||||
Adaptive Thresholding (AT) ( Adjustment), relative | 2 | 1 | 2 | 2 | 2 | 1 | 1 | 2 |
Threshold ( Trigger), mV | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Amplification ( Adjustment), relative | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Rejection Hz (LF) | 3 | 3.6 | 1.6 | 2 | 2.4 | 1.4 | 0.8 | 3 |
Cross Delay (channel), mc | 320 | |||||||
Cross Blocking | 2 |