When Axxon PSIM is installed, it is configured to operate with the Axxon PSIM MS SQL server database.
If the current database is stored in MS Access format, it needs to be converted to MS SQL format before Axxon PSIM connection setup. |
If Turkish Windows OS language pack and English localization of Axxon PSIM are used, then the connected database must have the Latin1_General_100_CI_AS value of the Collation parameter. In most cases, the default value of the parameter must be used. Ensure that you have the correct language settings in the operating system. |
To connect the Axxon PSIM Configuration database, do the following:
In the 1.Select or enter a server name line, select from the list or enter the name of MS SQL server that is used to store the database to which you want to connect.
In case you use dynamic host configuration protocol (DHCP) for the local database, set 127.0.0.1 IP address (without using computer names and local value) in the 1.Select or enter a server name. Set 127.0.0.1 value when the static IP address is used. Otherwise, Axxon PSIM is disconnected with its local database when network cable is disconnected. If Axxon PSIM is connected to remote database configuration by IP address (for example, 192.168.0.68\SQLEXPRESS), you cannot change and save Axxon PSIM settings when there is a network connection break. If event protocol is extracted into an individual database, use any functioning way to specify a server name. |
If MS SQL server authentication is performed through the user Windows OS account, switch to the Use Windows NT Integrated security position.
If conversion is performed via the remote SQL server, the computer with MS SQL server installed must show the current user account. And the user is logged on under this account at the computer that performs the database connection. |
Go to the All tab.
In the Persist Security Info field, set the True value. This is necessary to correctly save the user password.
Each time you change the server connection parameters, you must set the Persist Security Info field value to True. |
You must select a database at this step. If you leave the database field blank, after you close the Data Link Properties window, the line "Database is not set in connection settings" appears in the database description window of the IDB.exe utility and the OK button to save changes is inactive. |
We strongly recommend updating the database structure after this. For this, click the Update database button in the idb.exe utility dialog window. If DB is not updated at this step, the update is automatically performed at Axxon PSIM start-up, however, it might be difficult to track errors in this case.
If the Event Viewer is in the individual database (see Extracting event protocol into an individual database), then the Event Viewer database structure will be updated when updating the main database structure. So we recommend checking the connection to the Event Viewer database before updating the main database structure in order to prevent any errors. |
Axxon PSIM database is now connected.