To create the People counter detector, do the following:
People counter counts the number of people in the specified area using the metadata of the Human pose detector.
An event, on the basis of which a macro can be started (see Configuring start conditions), can be generated if the number of people in the frame meets the specified conditions.
|
If necessary, you can change the detector parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Object features | ||
Record mask to archive | Yes | Mask is recorded to the archive by default. To disable the parameter, select the No value |
No | ||
Other | ||
Enable | Yes | The detector is enabled by default. To disable the detector, select the No value |
No | ||
Name | People counter | Enter the detector name or leave the default name |
Type | People counter | Name of the detector type (non-editable field) |
Basic settings | ||
Alarm when value | In range | Specify when the detector must generate an event: when the number of people in the specified area is within the set range or out of the range |
Out of range | ||
End value of alarm range settings | 100 | Specify the range of the number of people in the frame. The value must be in the range [0, 100] |
Event interval | 1 | Specify the interval in seconds between two consecutive events of the detector when the number of people in the frame continuously meets the specified conditions. The value must be in the range [1, 10000] |
Number of measurements in a row to trigger detection | Specify the minimum number of frames with the set number of people for the detector to generate an event. The value must be in the range [1, 20]. | |
Start value of alarm range settings | 5 | Specify the range of the number of people in the frame. The value must be in the range [0, 100] |
By default, the entire frame is the area for detection. In the preview window, you can specify the areas for detection using the anchor points (see Configuring a detection area).
|
To save the parameters of the detector, click the Apply button. To cancel the changes, click the Cancel
button.
Configuration of the People counter is complete.
In the Surveillance window on the layout next to the counter icon, you can add text and the number of people counted by the detector (see Displaying the number of detected objects).