To display the events in the Operator Protocol, it is necessary to explicitly specify the objects the events from which are to be received and processed:
Go to the Operator protocol object settings panel.
Specify the objects the events from which are to be received and processed in the Objects table (1):
Events are not displayed in the Operator protocol if not any objects selected. |
Select the object type in the list of the Type column.
Only objects for which the "INFORMATION" or "ALARM" value is selected in the Processing messages column on the Events tab in the ddi.exe utility are available for selection (see The Events tab section). |
In the list of the Event type column, select events that are to be displayed in the protocol box. If the event type is not specified, then all events registered by the selected object will get to the protocol.
If the processing of an event is to be confirmed with a password, select the Yes value in the Request password dropdown list. If there is no need to confirm the processing with a password, select the No value in this dropdown list.
If the processing of all events is to be confirmed with a password, set the Password for closing checkbox checked (see Setting the options for handling events in the Operator protocol). |
Repeat actions described in step 2 for all required objects. To add a line, go to the last line of the table and click the ↓ key.
To add a row to the table, select the last row and press the ↓ button on the keyboard. To remove the lines from the table, use the Ctrl + Del key combination. |