Documentation for Axxon One 3.0/3.1 version. Documentation for Axxon One 2.0 version is also available.


Attention!

  • We recommend using the PosXml driver for correct operation. If necessary, you can use the MixForward utility with the corresponding plugin to integrate the existing POS systems.
  • If you don't use PosXml, the event source operation in the Linux OS as well as the use of Axxon One reports is unavailable.

To configure the connection of the POS device, create the Event source object, the POSLegasy model (see Event source object).

If necessary, you can change the POS device connection parameters listed in the table:

ParameterValueDescription
Object identification
NameEvent sourceEnter the name of the object or leave the default name
Short name1Enter the short name of the object or leave the default name. By default, the sequence number of the event source is specified
ID1Object ID. By default, the sequence number of the event source is specified (non-editable field)
Object features
Vendor/Driver familyCommaxSelect the vendor of the event source. POSLegacy is selected by default
Commax Complex Server
Live Eye
POSLegacy
PosXml
ModelPOSLegacy DeviceSelect the device model
Model namePOSLegacy DeviceName of the device model (non-editable field)
FirmwareautoEnter the version of the device firmware. The default value is auto
MAC address-Enter the MAC address of the device
Address0.0.0.0Enter the IP address of the device
Use device settingsYesBy default, the parameter is enabled. If you don't want to use device settings, select the No value
No
Break unused connectionsYesBy default, the parameter is disabled. If you want to break unused connections, select the Yes value
No
Device serial number
If necessary, enter the valid serial number of the device
Geolocation
Latitude0Enter the geolocation latitude of the device. The value must be in the range [-90, 90]. The default value is 0
Longitude0Enter the geolocation longitude of the device. The value must be in the range [-180, 180]. The default value is 0
Azimuth0Enter the angle between the north vector and the object vector in the horizontal plane. The value must be in the range [0, 360]. The default value is 0
Authentication
DefaultYesBy default, the parameter is enabled. If you don't want to use the default authentication settings, select the No value
No
Username
If necessary, enter the username for authentication
Password
If necessary, enter the user password for authentication
Other
EnabledYesBy default, the event source is enabled. To disable the event source, select the No value
No
Port2555Enter the port to connect the POS device. The value must be in the range [0, 65535]. The default value is 2555
Background colorBlack; 0; 0; 0Select the background color for the caption output
Beginning words

Click the button on the right side of the line. In the String Collection Editor window that opens, enter the words that mark the beginning of the receipt

Note

  • You can enter an unlimited number of words.
  • Enter each line of words in a new line.
Connection speed





300Select the speed of connection via COM port from the list
600
1200
2400
4800
9600
14400
19200
38400
56000
57600
115200
128000
Display duration10Enter the display duration of the accumulated group of lines in seconds. The value must be in the range [1, 2147483647]
DOS to WIN ConversionYesBy default, the parameter is disabled. If data from the POS device is sent in DOS encoding, select the Yes value
No
End words

Click the button on the right side of the line. In the String Collection Editor window that opens, enter the words that mark the end of the receipt

Note

  • You can enter an unlimited number of words.
  • Enter each line of words in a new line.
Erase upon completionYesBy default, the parameter is disabled. If it is not necessary to display the lines appearing in the receipt after the end words, select the Yes value
No
FontCourier New; 12pt; color=255; 255; 255Select the font parameters for caption display
Ignore CaseYesBy default, the parameter is enabled. If word case must be taken into account when determining the start and end of the receipt, select the No value
No
Initial UTF-8 FormatYesBy default, the parameter is disabled. If data from the POS device is sent in UTF-8 encoding, select the Yes value to ensure the correct display of captions
No
Message handling methodLinearlySelect the message handling method from the list
JSON
By event
Parity ControlNoneSelect parity control for data transmission via COM port
Even
Odd
Repeats ProcessingNoneSelect the mode of repeats processing from the list
Ignore repeats
Retalix POS terminalYesBy default, the parameter is disabled. If you use a Retalix POS terminal, select the Yes value
No
Sample timestap offset0Enter the time offset for caption display in milliseconds. The value must be in the range [-5000, 5000]. The default value is 0
Template file
Enter the path to the parser template file
Terminal typeNone, DOS TO WIN, LATVIAN, WINCOR LATVIAN, RUSSIAN SIEMENS, SUPERMAG UKM, POSITOUCH, FIT, Marketer ISM 3000, G2, XML PROTOCOL, ASTOR, POS CASIO CHINESE, IBM LAN, VECTRON, POSWARE, HRK, POWERTILL, ALOHA, CASIOHQT2100, SHARP, WINCOR SPANISH, CRS 3000, NCR USA, SMARTFUEL, OBI ONE, OBI TWO, HRK PRINTER, VESY 01, ALPHA_AB, SHARP 02, MICROS SUBWAY, INTEC TPV SQL, Samsung SAM4S 7000 Series, IBM Spanish, WINCOR SPANISH M, WINCOR SPANISH M1, KKM, CRYSTAL UKM 323, MICROS XML, POS E-LECLERC, EPSON, TEC 1595, TruckScale1, TruckScale2, WINCOR SPANISH M2, MAXISHOP10, IBMMAC, DEBUG POS, D STORE, SPSRX Express, BC4000, MICROS 9700, WINCOR BA63, WINCOR_CASHCARRY, ARCH SOFTWARE, IKEA POLAND, GLORY_USFS1, COOEC, PRECIA MOLEN, SYMBOL_FZ_LS3408_BARCODE_SCANNER, HONEYWELL_HYPERION_1300U, WINCOR_NIXDORF_BEETLE_M2_POSPROM_SUITE, ANDROID_BARCODE_SCANNER, BOUNDARYSelect the type of POS device from the drop-down list
Timeout100Enter the timeout. The value must be in the range [10, 3000]. The default value is 100
Transport ProtocolTCPSelect the data transmission protocol from the drop-down list
UDP
RS-232
UPD packet maximum size4096Enter the maximum size of the UDP packet in bytes. Packets that exceed the specified size aren't accepted. The value must be in the range [0, 65536]. The default value is 4096

Connection of the POS device is complete.

  • No labels