Go to documentation repository
Attention!
To configure the connection of the POS device, create the Event source object, the POSLegasy model (see Event source object).
If necessary, you can change the POS device connection parameters listed in the table:
| Parameter | Value | Description |
|---|---|---|
| Object identification | ||
| Name | Event source | Enter the name of the object or leave the default name |
| Short name | 1 | Enter the short name of the object or leave the default name. By default, the sequence number of the event source is specified |
| ID | 1 | Object ID. By default, the sequence number of the event source is specified (non-editable field) |
| Object features | ||
| Vendor/Driver family | Commax | Select the vendor of the event source. POSLegacy is selected by default |
| Commax Complex Server | ||
| Live Eye | ||
| POSLegacy | ||
| PosXml | ||
| Model | POSLegacy Device | Select the device model |
| Model name | POSLegacy Device | Name of the device model (non-editable field) |
| Firmware | auto | Enter the version of the device firmware. The default value is auto |
| MAC address | - | Enter the MAC address of the device |
| Address | 0.0.0.0 | Enter the IP address of the device |
| Use device settings | Yes | By default, the parameter is enabled. If you don't want to use device settings, select the No value |
| No | ||
| Break unused connections | Yes | By default, the parameter is disabled. If you want to break unused connections, select the Yes value |
| No | ||
| Device serial number | If necessary, enter the valid serial number of the device | |
| Geolocation | ||
| Latitude | 0 | Enter the geolocation latitude of the device. The value must be in the range [-90, 90]. The default value is 0 |
| Longitude | 0 | Enter the geolocation longitude of the device. The value must be in the range [-180, 180]. The default value is 0 |
| Azimuth | 0 | Enter the angle between the north vector and the object vector in the horizontal plane. The value must be in the range [0, 360]. The default value is 0 |
| Authentication | ||
| Default | Yes | By default, the parameter is enabled. If you don't want to use the default authentication settings, select the No value |
| No | ||
| Username | If necessary, enter the username for authentication | |
| Password | If necessary, enter the user password for authentication | |
| Other | ||
| Enabled | Yes | By default, the event source is enabled. To disable the event source, select the No value |
| No | ||
| Port | 2555 | Enter the port to connect the POS device. The value must be in the range [0, 65535]. The default value is 2555 |
| Background color | Black; 0; 0; 0 | Select the background color for the caption output |
| Beginning words | Click the button on the right side of the line. In the String Collection Editor window that opens, enter the words that mark the beginning of the receipt Note
| |
| Connection speed | 300 | Select the speed of connection via COM port from the list |
| 600 | ||
| 1200 | ||
| 2400 | ||
| 4800 | ||
| 9600 | ||
| 14400 | ||
| 19200 | ||
| 38400 | ||
| 56000 | ||
| 57600 | ||
| 115200 | ||
| 128000 | ||
| Display duration | 10 | Enter the display duration of the accumulated group of lines in seconds. The value must be in the range [1, 2147483647] |
| DOS to WIN Conversion | Yes | By default, the parameter is disabled. If data from the POS device is sent in DOS encoding, select the Yes value |
| No | ||
| End words | Click the button on the right side of the line. In the String Collection Editor window that opens, enter the words that mark the end of the receipt Note
| |
| Erase upon completion | Yes | By default, the parameter is disabled. If it is not necessary to display the lines appearing in the receipt after the end words, select the Yes value |
| No | ||
| Font | Courier New; 12pt; color=255; 255; 255 | Select the font parameters for caption display |
| Ignore Case | Yes | By default, the parameter is enabled. If word case must be taken into account when determining the start and end of the receipt, select the No value |
| No | ||
| Initial UTF-8 Format | Yes | By default, the parameter is disabled. If data from the POS device is sent in UTF-8 encoding, select the Yes value to ensure the correct display of captions |
| No | ||
| Message handling method | Linearly | Select the message handling method from the list |
| JSON | ||
| By event | ||
| Parity Control | None | Select parity control for data transmission via COM port |
| Even | ||
| Odd | ||
| Repeats Processing | None | Select the mode of repeats processing from the list |
| Ignore repeats | ||
| Retalix POS terminal | Yes | By default, the parameter is disabled. If you use a Retalix POS terminal, select the Yes value |
| No | ||
| Sample timestap offset | 0 | Enter the time offset for caption display in milliseconds. The value must be in the range [-5000, 5000]. The default value is 0 |
| Template file | Enter the path to the parser template file | |
| Terminal type | None, DOS TO WIN, LATVIAN, WINCOR LATVIAN, RUSSIAN SIEMENS, SUPERMAG UKM, POSITOUCH, FIT, Marketer ISM 3000, G2, XML PROTOCOL, ASTOR, POS CASIO CHINESE, IBM LAN, VECTRON, POSWARE, HRK, POWERTILL, ALOHA, CASIOHQT2100, SHARP, WINCOR SPANISH, CRS 3000, NCR USA, SMARTFUEL, OBI ONE, OBI TWO, HRK PRINTER, VESY 01, ALPHA_AB, SHARP 02, MICROS SUBWAY, INTEC TPV SQL, Samsung SAM4S 7000 Series, IBM Spanish, WINCOR SPANISH M, WINCOR SPANISH M1, KKM, CRYSTAL UKM 323, MICROS XML, POS E-LECLERC, EPSON, TEC 1595, TruckScale1, TruckScale2, WINCOR SPANISH M2, MAXISHOP10, IBMMAC, DEBUG POS, D STORE, SPSRX Express, BC4000, MICROS 9700, WINCOR BA63, WINCOR_CASHCARRY, ARCH SOFTWARE, IKEA POLAND, GLORY_USFS1, COOEC, PRECIA MOLEN, SYMBOL_FZ_LS3408_BARCODE_SCANNER, HONEYWELL_HYPERION_1300U, WINCOR_NIXDORF_BEETLE_M2_POSPROM_SUITE, ANDROID_BARCODE_SCANNER, BOUNDARY | Select the type of POS device from the drop-down list |
| Timeout | 100 | Enter the timeout. The value must be in the range [10, 3000]. The default value is 100 |
| Transport Protocol | TCP | Select the data transmission protocol from the drop-down list |
| UDP | ||
| RS-232 | ||
| UPD packet maximum size | 4096 | Enter the maximum size of the UDP packet in bytes. Packets that exceed the specified size aren't accepted. The value must be in the range [0, 65536]. The default value is 4096 |
Connection of the POS device is complete.