Go to documentation repository
Previous page Next page
The Backup archive panel object is used to register and configure the Backup archive panel interface object in Axxon PSIM, which allows the operator to configure video data archiving.
The settings panel of the Backup archive panel object is shown in the figure.
The table describes the setting parameters corresponding to the elements of the settings panel of the Backup archive panel interface object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* | Automatically | Displays the number of the Backup archive panel | Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Backup archive panel objects in the video surveillance system with distributed architecture |
2 | The Name* | Enter the value in the field | Sets the name of the Backup archive panel object | Latin alphabet, Cyrillic, digits and service characters | Backup archive panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable | Set the checkbox | Disables the Backup archive panel object | Boolean type | Clear | Set—the Backup archive panel object is disabled and isn't used Clear—the Backup archive panel object is enabled and used |
4 | The Display | Select the value from the list | Sets the Display parent object of the system with distributed architecture to which the given Backup archive panel object belongs | Names of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the video surveillance system with distributed architecture |
5 | The Backup archive* drop-down list | Select the value from the list | Sets the backup archive, which the operator will control using the Backup archive panel object | Names of the Backup archive objects registered in the system | Backup archive | Depends on the number of the Backup archive objects in the video surveillance system with distributed architecture |
The Window parameters group | ||||||
6 | The Fixed position | Set the checkbox | Allows moving the backup archive panel on the screen using the mouse | Boolean type | Clear | Set—the backup archive panel cannot be moved Clear—the backup archive panel can be moved |
The X field | Enter the value in the field. Note. Automatically, if the Fixed position checkbox is set | Sets the X coordinate in the horizontal axis for the upper left corner of the backup archive panel on the screen | % of the screen width | 10 | From 0 to M*100, where M is the number of the installed monitors | |
The Y field | Enter the value in the field. Note. Automatically, if the Fixed position checkbox is set | Sets the Y coordinate in the vertical axis for the upper left corner of the backup archive panel on the screen | % of the screen height | 10 | From 0 to M*100, where M is the number of the installed monitors | |
The W field | Enter the value in the field. Note. Automatically, if the Fixed position checkbox is set | Sets the width of the Backup archive panel | % of the screen width | 80 | From 0 to M*100, where M is the number of the installed monitors | |
The H field | Enter the value in the field. Note. Automatically, if the Fixed position checkbox is set | Sets the height of the Backup archive panel | % of the screen width | 80 | From 0 to M*100, where M is the number of the installed monitors | |
The button | Click the bottom | Opens the window for setting the position and size of the Backup archive panel object using the mouse | NA | NA | NA |
*Name of the element isn't displayed in the settings panel of the given object