Go to documentation repository
Previous page Next page
Axxon PSIM allows connecting devices via the chinese standard GB/T28181. This protocol is based on the SIP over UDP protocol (and over TCP starting with the GB/T28181-2016 version). The GB/T28181 protocol uses the following protocols over SIP:
This allows receiving the status of sensors, events from detectors, PTZ and relays control, access to the embedded archive of the IP device (you must set the correct device time zone in Axxon PSIM beforehand), within the SIP session, and so on. The operation with single-channel and multi-channel devices in single-stream mode and with the UDP and TCP transport protocols is also supported.
At the same level of the OSI model, the RTP/RTCP protocol also works in parallel with the SIP protocol, which makes it possible to use the following functions:
For the most up-to-date information on this standard and the features supported in Axxon PSIM, see the Documentation Drivers Pack.
To configure IP devices connected via the GB/T28181 protocol, use the web interface of these IP devices. The settings aren't sent from Axxon PSIM to the device.
Before you connect the IP device via this protocol to Axxon PSIM, you must set the SIP settings on the IP device in the following way:
Note
See also Examples of IP device settings for connection via GB/T28181 standard.
Attention!
The system supports the operation of IP devices via the GB/T28181 protocol with no more than one SIP server. This means that you can create several Video capture device objects with the GBT28181 type in the Axxon PSIM hardware tree, however, the part of the address after @ must match for all of them. The server ID, local address, external address, and port must be the same for all devices. If at least one parameter is different (for example, the local IP address isn't set for some device when it is set for other devices), then such a device doesn't start.
Note
After you configure the device as described above, add it to Axxon PSIM as follows:
Examples
34020000001320000008@34020000002000000001
34020000001320000008@34020000002000000001-10.0.40.246/113.125.160.58
34020000001320000008@34020000002000000001-10.0.40.246
34020000001320000008@34020000002000000001-/113.125.160.58
34020000001320000008/50200@34020000002000000001
34020000001320000008/50200-50210@34020000002000000001-10.0.40.246
In the Port field (5), enter the local port number that the Axxon PSIM server will "listen" to receive messages from the IP device.
Usually this is the default SIP port—5060.
Note
The SIP port of the IP device is detected automatically.
Further work with the device (for example, displaying video on the monitor, archive recording) is performed using the created Camera object—see the Configuring video subsystem section in the Administrator's Guide document. The PTZ and relay management functions, access to the embedded storage, and so on are configured in the same way as for ordinary IP devices and described in the corresponding sections of this document Guide for installing and configuring security system components.
Adding the device that operates via the GB/T28181 protocol is complete.