Go to documentation repository
Previous page Next page
You must configure the Hikvision DS-1200KI PTZ control device in the following way before creating the corresponding object in Axxon PSIM:
Set the Axxon PSIM IP address and server port on the device. To do this, you must open the device web interface by the address set in the previous step and select Platform Access → Third-Party Platform.
Note
By default, the web interface is only available on https, so enter the https prefix before the IP address.
Select any monitor MON (monitor) [an integer in the range 1—9999] and any group of cameras CAM-G (camera group) [an integer in the range 1—999999]; in this mode, only the MULT, OK keys and the rotations of the joystick axes work.
Note
To select these parameters, enter a number from the device keypad, and then press the corresponding key (MON/WIN/CAM/CAM-G).
If the server IP address and/or port aren't available from the PTZ control device, then after you press the MON/WIN/CAM/CAM-G keys, the "Connect failed" message is displayed on the control device screen.
Preconfiguring the Hikvision DS-1200KI PTZ control device is complete.
Note
Before you start configuring the control device in Axxon PSIM, make sure that the 1 value is assigned to the DisableInternalJoystick registry key (that is, the default value, see Registry keys reference guide).
To configure the connection of the Hikvision DS-1200KI control device in Axxon PSIM, do the following:
Configuring the connection of the Hikvision DS-1200KI control device in Axxon PSIM is complete.
When you press the MULT, PRESET, PATROL, or PATTERN keys on the control device, the following actions are performed:
The link contains a file with a script in the JScript language, which allows you to assign actions to the keys of the Hikvision DS-1200KI telemetry control panel in the following way:
Key | Code | Action |
| CAM | 21 | Select a camera |
| MON | Select a monitor | |
| WIN | Used along with the digital buttons to select the surveillance window | |
| PRESET | 22 | Used along with the digital buttons to open a preset |
| IRIS+ | 7 | Increase the iris value |
| IRIS- | 8 | Decrease the iris value |
| PATROL | 17 | |
| PATTERN | 18 | |
| PREV | 15 | Switch to the previous camera |
| NEXT | 16 | Switch to the next camera |
| CAM-G | 20 | Used along with the digital buttons to select a group of cameras |
| ZOOM+ | 1 | Zoom in |
| ZOOM- | 2 | Zoom out |
| WIPER | 6 | Enable the wiper |
| LIGHT | 5 | Enable the backlight |
| FOCUS+ | 3 | Increase the focal length |
| FOCUS- | 4 | Decrease the focal length |