Documentation for Axxon PSIM 2.0. Documentation for other versions of Axxon PSIM is available too.

Previous page Next page


On the page:

Connect

Connect(BSTR ip, BSTR login, BSTR password, BSTR arch_password, long param, long port) sets a connection to the server/video gate/backup archive.

  • BSTR ipIP address of the server.
  • BSTR loginlogin to connect to the server (can be blank).
  • BSTR passwordpassword to set up a connection to the server (can be blank).
  • BSTR arch_passwordpassword to access the archive (that is, admin password, can be blank).

  • long paramserver role. The parameter is mandatory.
    • 0video server.
    • 1—online archive.
    • 2video gate.

  • long portport to connect to server. 
    • if 0, 1, or 2 are passed, the connection is established with the port 900, 901, or 902, correspondingly.

    • if 100 is passed, the connection is to the port 10504.

    • if any other value is passed, the connection is with the port number "port + 20000". For example, if port=900, the connection is established with server port 20900.

The connection to the server is set up asynchronously.

Attention!

If login and password are not specified at the Connect() method call, all cameras are viewable in the control. If differentiation of permissions is important, this must be taken into account at the development stage.

ShowCam

ShowCam(long cam_id, long compress, long show) shows/hides the camera on the monitor.

  • long cam_idcamera ID.
  • long compresslevel of video compression 0-5 (for local camera =0). If set to -1, video stream is displayed directly from the camera without compression
  • long showcheckbox: show/hide camera (1/0)

DoReactMonitor

DoReactMonitor(BSTR react_string)—control monitor/camera behavior.

  • BSTR react_stringreaction string view

How to create react_string:

react_string = "MONITOR||ARCH_FRAME_TIME|cam<3>,date<dd-mm-yy>,time<hh:mm:ss>";

CamMonitor1->DoReactMonitor(react_string);

The result of calling the function with this parameter: camera 3 is switched to the archive mode, and the archive is positioned to date "dd-mm-yy" and time "hh:mm:ss" (date and time must be set in this format only).

The mode parameter can take the following values:

0video gate if it's specified (otherwise, video server).

1video server.

2—backup archive.

“MONITOR|<id ignored>|ARCH_FRAME_TIME|...”

Note

Optionally, you can also specify positioning accuracy down to milliseconds, for example:

DoReactMonitor(“MONITOR||ARCH_FRAME_TIME|cam<3>,date<02-10-05>,time<12:12:22.345>,mode<1>")

Example. Show the second stream from camera 14 on monitor 1:

"MONITOR|1|ADD_CAM|cam<14>,cam_id<14>,compress<1>,stream_id<14.2>"

Exapmle. Set FPS = 1 when viewing archive from camera 11:

"MONITOR||CAM_PARAMS|cam<11>;arch_fps<1>"

Example. Get the coordinates of the fisheye camera 1 in the monitor (Monitor 1):

"MONITOR|1|GET_CAM_PARAMS|cam<1>"

RemoveAllCams

RemoveAllCams() : longremove all cameras from the monitor.

IsConnected

IsConnected() : booleanmethod shows if the video server is connected or disconnected.

GetCurIp

GetCurIp() : BSTRreturns the IP address of the server specified when calling Connect.

SendRawMessage

SendRawMessage(BSTR msg)send the command to be executed to video server.

  • BSTR msgcommand string view.

How to call a function:

m_Cam.SendRawMessage("CAM|1|REC");
m_Cam.SendRawMessage("CAM|1|REC_STOP");
m_Cam.SendRawMessage("CAM|1|ARM");
m_Cam.SendRawMessage("CAM|1|DISARM");

Disconnect

Disconnect()disconnect from the video server. 

SetCallBackOptions

SetCallBackOptions(int cam_id, int options)sets parameters to get video from camera.

  • int cam_idcamera ID (number).
  • int optionsoptions. The possible values of the options parameter are:
    • WithoutVideoFrame = 0x00do not send frames from the video module.
    • WithVideoFrame = 0x01send frames from the video module.
    • WithExtendedParams = 0x02get frames with extended parameters (time, FPS, captions).
    • WithInformationLayout = 0x04display video in the window with control elements (context menu).
    • WithCompressedData = 0x08display video in the original format without decompression (if any).
    • WithoutDecode = 0x10disable video decoding on the server.
    • WithoutSubtitles=0x20disable subtitles.

Note

The options parameter is formed in the same way as the parameters of the CamMonitor.ocx component (see CamMonitor.ocx parameters).

SetParam

SetParam(BSTR param_name, BSTR param_value)sets the number of camera windows in CamMonitor.

  • BSTR param_namea string representation of the length or width.
  • BSTR param_valuethe number of camera windows.

How to call a function:

m_cam.SetParam("monitor_ch", m_NH);
m_cam.SetParam("monitor_cw", m_NW);
  • No labels