Go to documentation repository
You can restrict the access level of the Gate users, so that access is provided only through one controller reader.
To do this, you need to switch the controller to Two-door pass (it is set by connecting straps, see documentation for the controller) and configure time schedules so that their first interval refers to the first reader and the second interval refers to the second reader.
For example, if you want to grant access only through the first reader to an employee who has Access level for entry and grant access only through the second reader to an employee who has Access level for exit, make the following settings in the Access Manager module (see Creating a time zone in the Access Manager software module and Creating access levels):
- Create and configure the time schedule for entry.
- Create and configure the access level for entry by specifying the previously created time schedule for entry for the Gate Parking access point.
- Create and configure the time schedule for exit.
- Create and configure the access level for exit by specifying the previously created time schedule for exit for the Gate Parking access point.