To configure the AR-716 controller, do the following:
- Go to the AR-716 object's settings panel.
- In the Optional function settings section select the needed function settings checkboxes (1). Descriptions of all function settings of the AR-716 controller see in the vendor documentation.
- In the Relay timings, 10ms section enter the time of relay activation (default time is 5 sec.) (2).
- In the Readers of channel 1 section select those door readers which are connected to the Channel 1 (3).
- In the Readers of channel 2 section select those door readers which are connected to the Channel 2 (4).
- Click Set up Time Zones to configure the matching between time zones of device and time zones of Intellect Server (5) .
- In the Intellect TZ column select the time zone in ACFA Intellect corresponding to the time zone of Soyal device (1).
- Click OK to confirm changes (2).
- In the Intellect TZ column select the time zone in ACFA Intellect corresponding to the time zone of Soyal device (1).
- Click the Apply button.
Configuring parameters of the AR-716 controller is completed.