Traffic violations detection module object settings panel contains the following interface elements:
The following table describes the elements of the Traffic violations detection object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Traffic lights signal dropdown list | Selecting the value in the list | Selecting «Sensor/Detector» object, by signal of which traffic light is detected | List of accessible «Sensor/Detector» objects | no | Depending on number of accessible «Sensor/Detector» objects |
2 | Draw a stop line checkbox | Setting check box | Draw a stop line on video in front of traffic light function activation | Boolean type | no | Yes – drawing a stop line function is active |
3 | Stop line settings button | Clicking | Access to stop line settings | - | - | - |
4 | Delay in violation registering field | Setting the value in the field | Set period after which the running a red light or stop will be considered as a violation | Millisecond | 1000 | 0-20000 |
5 | The number of frames to save field | Setting the value in the field | Set the number of frames to save in the database while the running a red light | Whole nonnegative number | 2 | From 1 to infinity |
6 | Frame saving interval field | Setting the value in the field | Set frame saving interval while the running a red light | Millisecond | 500 | 0-20000 |
7 | Type of violation drop-down list | Selecting the value in the list | Selecting the type of traffic violation that will be specified in the capture to the alarm when the Stop violation is registered | List of available violation types while the stopping – Stop over stop line or Stop over crosswalk line | Stop over stop line | - |
8 | The number of frames to save field | Setting the value in the field | Set the number of frames to save in the database when the Stop violation is registered | Whole nonnegative number | 2 | From 1 to infinity |
9 | Frame saving interval field | Setting the value in the field | Set frame saving interval when the Stop violation is registered | Millisecond | 500 | 0-20000 |