To operate the neural counter, a camera must match the following requirements:

  1. Minimum resolution is at least 640х480 pixels.
  2. Frame rate is no less than 2 FPS (no less than 4 FPS is recommended).
  3. Objects must be visually separated from the background as well as from each other.
  4. Camera is mounted in no less than 3 meters above the ground, or on the ceiling.
  5. An object (its bounding rectangle) must occupy no less than 10% of the FOV.

Attention!

We cannot guarantee normal operation of the neural counter with a fisheye camera.