The Web-server object is used for viewing the video surveillance information from an Internet browser and TCP/IP communication environment. The settings panel of the Web-server object is shown in figure.
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Web-server object.
№ | Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Web-server object in the digital distributed video surveillance system. | Sequence of numbers | - | From 1 and above. Depends on the number of the Web-server objects in the digital distributed video surveillance system. |
2 | Name* | Type-in the value in the field | Sets the name of the Web-server object in the digital distributed video surveillance system. | Latin, Cyrillic and service characters | Web- server | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Checkbox | Sets the state of the Web-server object (enabled or disabled) in the digital distributed video surveillance system. | Boolean type | No | Yes – the Web-server object is disabled and is not in use No – the Web-server object is enabled and is in use |
4 | Computer | Selected in the list | Sets the parent Computer object of the digital distributed video surveillance system, to which the given Web- server object refers. | Name of the Computer objects registered in the system | Name of the parent Computer object | Depends on the number of the Computer objects in the digital distributed video surveillance system |
The Cameras group | ||||||
5 | As in camera settings | Checkbox | Sets the transmission of video signal to Remote Workstations using the Web-server module. The compression level of this video signal is to be the same as it is for to the recorded and transmitted video signals or as it is set by the slider below the As in camera settings checkbox. | Boolean type | Yes | Yes – the compression level of the video signal transmitted with the Web- server module is be the same as the compression level of the recorded and transmitted video signal. No – the compression level of the video signal transmitted with the Web- server module is the same as one set by the slider below the As in camera settings checkbox |
6 | Signal compression* | Set the slider in the required position | Sets the compression level of the video signal transmitted with the Web-server module to the Remote Workstations. The higher the compression level, the lower the quality of video signal. The parameter is active, only if the As in camera settings checkbox is unchecked (i.e., the As in camera settings parameter has No value). |
| Min | Min – the minimal compression level, at which the video signal is transmitted as a non-compressed video. Max – maximum video signal compression level. |
The HTTP-server group | ||||||
7 | Port’s number | Type-in the value in the field | Sets the number of the port used by the HTTP server (for video surveillance with the Web-browser via the Internet). | Sequence of numbers | 80 | Any allowable port numbers which are not in use. The number of ports is defined by the system administrator. |
8 | Amount of connections | Type-in the value in the field | Sets the maximum allowable number of connections to the video server via the Web-server module. Each request to view the camera feed and each request to control all PTZ devices is considered as a user connection. | pcs | 100 | Any integer. In the case where 0 value is specified, video signals will not be displayed on the Web-server monitor. |
The Mobile-server group | ||||||
9 | Port’s number | Type-in the value in the field | Sets the number of the port for Mobile-server operations. | Sequence of numbers | 5003 | Any allowable port numbers which are not in use. The number of ports is defined by the system administrator. |
10 | Amount of connections | Type-in the value in the field | Sets the maximum allowable connections to the video server via the Web-server module. Each request to view the camera feed and each request to control all PTZ devices is considered as a user connection. | pcs | 100 | Any integral number. In the case where 0 value is entered, video signals will not be displayed in the Web server monitor. |
The Cameras group | ||||||
11 | Camera | Selected in the list | Sets the name of the video camera video from which is transmitted to the Remote Workstation via the Web-server module. | Names of the Camera objects registered in the system | Not set | Depends on the number of video surveillance cameras in the digital distributed video surveillance system |
12 | Gate | Selected in the list | Sets the name of videogate video from which is transmitted to the Remote Workstation via the Web-server. Note: If the Videogate has its own archive, then Web-server will get the archive from the Videogate archive, otherwise – from the main camera archive. | Names of the Videogate objects registered in the system | Not set | Depends on the number of videogates in the digital distributed video surveillance system |
13 | Microphone | Select from a list | Specifies the name of microphone associated with the camera from which the sound will be passed through the Web-server | Names of registered Microphone objects in the system | Not specified | Depends on the number of microphones in the video surveillance system |
14 | Speaker | Select from a list | Specifies the name of speaker associated with the camera which will be in use to playback sound received from the client | Names of registered Speaker objects in the system | Not specified | Depends on the number of speakers in the video surveillance system |
15 | Add all | Click the button | Adds all video cameras installed in the digital distributed video surveillance system to the list of cameras video from which is transmitted to the Remote Workstation via the Web-server | - | - | - |
16 | Clear | Click the button | Removes all video cameras from the list of cameras video from which is transmitted to the Remote Workstation via the Web-server | - | - | - |
17 | Default user | Selected in the list | Sets the user with rights and authorities to conduct video surveillance from the Remote Workstation via the Web-server | The names of users registered in the system and added to the rights | Not set | Depends on the number of users registered in INTELLECT™ |
*The name of the element is not displayed in the settings panel of the given object.