To configure discrete and alarm inputs of controller, do the following:

  1. Click the Entry parameters on the settings panel of the BioSmart PROX object.
  2. Set the following parameters for each discrete input:
  3. In the Active level list select the level of signal at discrete input at which the access sensor triggering is detected (Fig. 3.43, 1).


Fig. 3.4 3 Configuring discrete and alarm inputs of BioSmart PROX v.2 and BioSmart PROX-E controllers

  1. In the corresponding list select the relay of controller that is event-triggered on the discrete input (Fig. 3.43, 2).
  2. In the Event list select the type of event processed by controller when the signal of specified level arrives to discrete input (Table 3.42, Fig. 3.43, 3).

Table 3.4 2 Type of event processed by controller

Event type

Description

Not assigned

Signals from corresponding discrete input are not processed

Relay control button

Signal of specified level caused by pushing the button is processed

Access sensor

Signal of specified level caused by walking through the turnstile or the door is processed

Unlocking sensor

Signal of specified level caused by unlocking the relay is processed


  1. In the Timer field specify time (in milliseconds) of active state of the relay after its triggering (Fig. 3.43, 4).
  2. Specify the following parameters for each alarm input:
  3. In the Active level list select the level of signal occurring at alarm input – it triggers access sensor (Fig. 3.43, 5).
  4. In the Event list select the type of sensor which triggering causes controller action (door locking, door unlocking, fire alarm activation, Fig. 3.43, 6).
  5. Click the OK and then the Apply button.

Discrete and alarm inputs of controller are now configured.