Previous page Next page


To configure the AR-725 controller, do the following:

  1. Go to the AR-725 object's settings panel.
  2. From the Region In drop-down list select the Area located in the site of entry through this reader (1).
  3. From the Region Out drop-down list select the Area located in the site of exit through this reader (2).
  4. From the Mode drop-down list select the required mode of the controller (3). Possible modes are presented in the table.

    Mode

    Networking/ Stand-Alone

    User   Capacity

    Access Mode

    Auto-show Duty time

    Event log Capacity

    120 Holidays

    Anti force

    Time Zone

    Lift Control

    Anti-pass-back

    M4

    Networking/ Stand-Alone

    1,024/3,000 (725H)

    1.Card only.

    2.Card and PIN (4-digit PIN)+#.

    3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN) + #.

    Yes

    1200/1500 (725H)/3000 (757H)

    Yes

    Yes

    11

    32

    Yes

    M8

    Networking/ Stand-Alone

    1,024/3,000 (725H)

    1.Card only.

    2.Card and PIN (4-digit individual PIN) + #.

    3.Card or PIN (4-digit individual PIN).

    Yes

    1200/1500 (725H)/3000 (757H)

    Yes

    Yes

    11

    32

    Yes

  5. Set the Local language checkbox to display information in the local language (4).
  6. Set the Auto reset APB checkbox to enable the auto reset of anti-passback data (5).
  7. Set the Disable WG0 and WG1 signal output checkbox to disable WG0 and WG1 outputs (6).
  8. Set the Trigger alarm for expiry user checkbox to enable alarm for expiry user (7).
  9. From the RS 485 port functions dropdown list select the type of communication through the RS 485 port (8).

    Attention!

    To connect the AR-725 controller with the ACFA Intellect software select «Host» value in the «RS 485 port functions» field (5).

  10. In the Duress: field of Passwords section enter the code using which the computer opens door and at the same time sends a message for help (9).
  11. In the Master: field of Passwords section enter the code which allows programming device (10).
  12. In the Common Timings section enter the required value in the corresponding fields (11).
  13. In the Main port options section specify the required settings of the main port of the controller (12).
  14. In the Main WG options section specify the required settings of the WG reader (13).
  15. Click Set up Time Zones to configure the matching between time zones of device and time zones of Intellect Server (14) .
    1. In the Intellect TZ column select the time zone in ACFA Intellect corresponding to the time zone of Soyal device (1).
    2. Click OK to confirm changes (2).
  16. Click the Apply button.

Configuring parameters of the AR-725 controller is completed.