Connect(BSTR ip, BSTR login, BSTR password, BSTR arch_password, long param, long port) sets a connection to the server/video gate/backup archive.
BSTR arch_password—password to access the archive (that is, admin password, can be blank).
2—video gate.
if 0, 1, or 2 are passed, the connection is established with the port 900, 901, or 902, correspondingly.
if 100 is passed, the connection is to the port 10504.
if any other value is passed, the connection is with the port number "port + 20000". For example, if port=900, the connection is established with server port 20900.
The connection to the server is set up asynchronously.
Attention!
If login and password are not specified at the Connect() method call, all cameras are viewable in the control. If differentiation of permissions is important, this must be taken into account at the development stage.
ShowCam(long cam_id, long compress, long show) shows/hides the camera on the monitor.
DoReactMonitor(BSTR react_string)—control monitor/camera behavior.
How to create react_string:
react_string = "MONITOR||ARCH_FRAME_TIME|cam<3>,date<dd-mm-yy>,time<hh:mm:ss>"; CamMonitor1->DoReactMonitor(react_string);
The result of calling the function with this parameter: camera 3 is switched to the archive mode, and the archive is positioned to date "dd-mm-yy" and time "hh:mm:ss" (date and time must be set in this format only).
The mode parameter can take the following values:
0—video gate if it's specified (otherwise, video server).
1—video server.
2—backup archive.
“MONITOR|<id ignored>|ARCH_FRAME_TIME|...”
Note
Optionally, you can also specify positioning accuracy down to milliseconds, for example:
DoReactMonitor(“MONITOR||ARCH_FRAME_TIME|cam<3>,date<02-10-05>,time<12:12:22.345>,mode<1>")
Example. Show the second stream from camera 14 on monitor 1:
"MONITOR|1|ADD_CAM|cam<14>,cam_id<14>,compress<1>,stream_id<14.2>"
Exapmle. Set FPS = 1 when viewing archive from camera 11:
"MONITOR||CAM_PARAMS|cam<11>;arch_fps<1>"
Example. Get the coordinates of the fisheye camera 1 in the monitor (Monitor 1):
"MONITOR|1|GET_CAM_PARAMS|cam<1>"
RemoveAllCams() : long—remove all cameras from the monitor.
IsConnected() : boolean—method shows if the video server is connected or disconnected.
GetCurIp() : BSTR—returns the IP address of the server specified when calling Connect.
SendRawMessage(BSTR msg)—send the command to be executed to video server.
How to call a function:
m_Cam.SendRawMessage("CAM|1|REC");
m_Cam.SendRawMessage("CAM|1|REC_STOP");
m_Cam.SendRawMessage("CAM|1|ARM");
m_Cam.SendRawMessage("CAM|1|DISARM");
Disconnect()—disconnect from the video server.
SetCallBackOptions(int cam_id, int options)—sets parameters to get video from camera.
Note
The options parameter is formed in the same way as the parameters of the CamMonitor.ocx component (see CamMonitor.ocx parameters).
SetParam(BSTR param_name, BSTR param_value)—sets the number of camera windows in CamMonitor.
How to call a function:
m_cam.SetParam("monitor_ch", m_NH);
m_cam.SetParam("monitor_cw", m_NW);